SENSIT Analog Output Calibration

Sensor

Apply a known load to sensor.      

Voltmeter

Connect the voltage output

of the IDA100 to a voltmeter.

Connect to USB 2.0 port 

for power

Computer

Summary of Contents for IDA100

Page 1: ...Quick Start Guide Sensor Solutions Source Load Torque Pressure Multi Axis Calibration Instruments Software www futek com IDA100 Digitally Configurable Amplifier with USB and Analog Output...

Page 2: ...pecifications without notice Please visit http www futek com salesterms for complete terms and conditions 10 Thomas Irvine CA 92618 USA Tel 949 465 0900 Fax 949 465 0905 www futek com TECHNICAL SUPPOR...

Page 3: ...4 Connections 6 Typical Connection Setups 7 SENSIT Test and Measurement Software 9 SENSIT Scale Method 10 SENSIT Analog Output Calibration 12 Shunt Adjustment and Zero Adjustment 15 Related Accessorie...

Page 4: ...Sensor Output Side 6 pin box mounted PT02E 10 6P LED Indicators See table on page 5 1 2 3 4 USB 2 0 Communication Link USB Bus Powered 5V Bipolar software selectable 5 VDC or 10 VDC Output Operating...

Page 5: ...5 3 4 LED INDICATORS Blinking blue 10 Hz Module Auto Calibration Blinking blue 1 Hz Module Normal Operation Green USB Power Red USB Data Link...

Page 6: ...unded on one end either the sensor instrument side or IDA100 side to avoid potential ground loops 6 PIN BENDIX PT02E 10 6P PIN COLOR DESCRIPTION A Excitation B Excitation C Signal D Signal E Green Vol...

Page 7: ...Connection Setups Sensor in Application Excitation Pin A Excitation Pin B Signal Pin C Signal Pin D PLC or Control Feedback System 10VDC Output or 5VDC output Vout Pin E GND Pin F USB 2 0 Connection...

Page 8: ...ical Connection Setups 5V USB Power Adapter Sensor in Application Excitation Pin A Excitation Pin B Signal Pin C Signal Pin D PLC or Control Feedback System 10VDC Output or 5VDC output Vout Pin E GND...

Page 9: ...the voltage readings can be scaled to a sensor capacity and display in an engineering unit such as grams Within SENSIT the IDA100 can be used with the Data Logging Mode and Live Graphing Mode Right cl...

Page 10: ...10 SENSIT Scale Method 10 1 2 3 4 5 6 7 8 9...

Page 11: ...g unit from the drop down menu Set the entered parameters Save the entered parameters Enable the Scale Method for the selected serial number Scale Method can be used to scale a V calibrated USB device...

Page 12: ...d adjustments are saved automatically FUTEK offers traceable system calibration services and can pair your sensor with the IDA100 for a plug and play type of usage For more information visit the FUTEK...

Page 13: ...atic Calibration Offset w Fixturing With only the fixture on the sensor click the Calibrate button to have the IDA100 self calibrate the zero Span 1 2 w Fixturing and click the Calibrate button to hav...

Page 14: ...14 SENSIT Analog Output Calibration Sensor Apply a known load to sensor Voltmeter Connect the voltage output of the IDA100 to a voltmeter Connect to USB 2 0 port for power Computer...

Page 15: ...Enter sensor s full mV V output Enter sensor output bridge resistance Choose 10V or 5V excitation to sensor Choose IDA100 full load output of 5VDC or 10VDC Choose if internal 150K ohm resistor will b...

Page 16: ...o or span 7 10 8 9 11 TIPS ON SHUNT AND ZERO ADJUSTMENT The calculation side will provide calculated shunt results from the provided parameters All adjustments made are live adjust ments and do not ne...

Page 17: ...17 Related Accessories USB 2 0 HI SPEED A B CABLE INCLUDED WITH FERRITE CHOKES Item Number GOD04123 6 PIN BENDIX MATING CONNECTOR INCLUDED Item Number GOD00046...

Page 18: ...10 Thomas Irvine CA 92618 USA Tel 949 465 0900 Fax 949 465 0905 www futek com...

Reviews: