background image

Author: FuturaSun 

Document name: Installation_manual_FuturaSun_2017 

Revision date: 07.08.2017 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

SAFETY AND 

INSTALLATION 

MANUAL 

 

Photovoltaic Module FU XXX P / M

 

Summary of Contents for FU M Series

Page 1: ...Author FuturaSun Document name Installation_manual_FuturaSun_2017 Revision date 07 08 2017 SAFETY AND INSTALLATION MANUAL Photovoltaic Module FU XXX P M...

Page 2: ...notice CONTENTS 1 General Information 3 2 Disclaimer of Liability 4 3 IEC 61215 61730 certifications 4 4 Limited Warranty 4 5 Module Specification 4 6 Safety Precautions 4 7 Installation 5 8 Use and...

Page 3: ...maximum power Impp Power Pmax with tolerance of 3 Solar radiation in W m2 at the time Temperature of the modules The general performance of the modules is heavily dependent on the intensity of the inc...

Page 4: ...allic jewelry and use insulated tools during installation Do not expose the modules to artificially concentrated sunlight Do not stand on drop scratch or allow objects to fall on the modules Do not li...

Page 5: ...on continuous base structures inclined or horizontal such as rails or similar Both base structures must be mounted at the same distance from the symmetrical axis vertical or horizontal of the module I...

Page 6: ...he mounting holes the drainage holes and the ground connection holes See the table of 60 and 72 cell module Mechanical drawing 60 cell module Mechanical drawing 72 cell module 7b Handling of Modules T...

Page 7: ...PV module is likely to experience conditions that produce more current and or voltage than reported at STC Accordingly the values of Isc and Voc marked on the module should be multiplied by a factor...

Page 8: ...will be approximately equal to Vocmod VocSTC Tmod 25 C x 0 125V Where o VocSTC is the open circuit voltage measured at STC o 0 125V C is the average variation of Voc of a module for a variation in tem...

Page 9: ...tion from mechanical stresses 9b How to Manage the Packaging Each package has been designed to allow the shipment and storage of modules in order to maintain their integrity unchanged over time provid...

Page 10: ...t During the handling of the pallet make sure to pay the utmost attention The packaging must be raised moved exclusively with fork lift trucks or hand pallet trucks fitted with forks of length appropr...

Page 11: ...isions without further notice 10 Temperature coefficients Technical data FU XXX P FU XXX M Voc temperature coefficient C 0 285 0 273 Isc temperature coefficient C 0 0474 0 0344 Pmax temperature coeffi...