in  order  to  be  protected  against  cutting  by  sharp 
edges and against skin burns. Handle the module 
in a way that avoids breakage or scratching of the 
front cover glass and mechanical damage to any 
other part of the module. Do not carry the module 
by its connector wires in order to avoid the risk of 
electric shock and prevent damage to the module. 
 
During  the  wiring  and  installation  of  the  modules 
use  caution!  Do  not  trample  on  or  scratch  the 
modules.  Do  not drop  sharp or  heavy  objects  on 
either surfaces of the module. Do not subject the 
modules to any impact, in particular in the vicinity 
of  the  edges  of  the  frames  and  do  not  flex  them 
mechanically.  The  modules  are  made of a single 
laminate,  therefore  once  damaged,  they  are  not 
repairable. 
 
In  the  event of  any damage  to either  the  front or 
the back of the module, the part exposed might be 
electrically  active  and  therefore  dangerous, 
especially if the module is connected in series to a 
string. 
 

7c) Electrical Connection 

Danger! 

Risk  of  serious  injury  or  death  from  electric  shock  or 
electric arc flash! Do not connect or disconnect modules 
under load!  

 
Even  if  the  modules  are  protected  against 
accidental  contact,  under  unfavorable  conditions 
high hazardous voltage (several hundreds of volts) 
may  occur  during  installation.  Consequently, 
installation  and  maintenance  of  the  modules,  as 
well as the connection to the main power supply, 
may only be performed by authorized and qualified 
persons. 

Before  connection  of  the  system  to  the 

grid, the PV system must be approved for correct 
installation,  by  an  electrician  responsible  to  the 
operator and the local electricity company. 
 

The design of the PV system should be done by a 
qualified  person  familiar  with  PV  system  design. 
The system design is the responsibility of the PV 
system  designer.  Therefore,  FUTURASUN  does 
not  assume  any  liability for how  the  modules  are 
installed.  

Under normal conditions, a PV module is likely 
to  experience  conditions  that  produce  more 
current  and/or  voltage  than  reported  at  STC. 
Accordingly,  the  values  of  I

sc

  and  V

oc

  marked 

on the module should be multiplied by a factor 
of  1.25  when  determining  component  voltage 
ratings, conductor current ratings, fuse sizes, 
and  size  of  controls  connected  to  the  PV 
output.  

 

The FU modules are qualified in protection class II 
as  for  the  class  of  protection  against  electrical 
shock in accordance with IEC 61730-1:2016.  
 
Also note: 

 

Grounding:

 The module frame or array must 

be grounded before wiring. For grounding, use 
material that is certified according to CEI 82/25 
or applicable national codes – in particular the 
grounding should be performed by a qualified 
electrician. 

Ensure that the grounding area for 

the  wire  is  clean  and  free  from  oxides  or  any 
debris  that  could  impede  the  electrical 
grounding.

 Attach a separate approved ground 

wire  to  one  of  the  holes  marked  with  ground 
label  on  the  module  frame  with  an  IEC 
approved ring terminal or IEC listed grounding 
lug.  

 

  V

oc

 should be increased by a factor according 

to  the  lowest  ambient  air  temperatures 
expected for the installation site. Refer to CEI 
82/25  for  the  correct  V

oc

  correction  factor 

according  to  the  respective  temperatures.  If 
this  information  is  not  available,  a  1.25 
multiplying factor can be used as default value 

for correction of V

oc

 

  In order to obtain the required electrical current 

and/or voltage, the modules can be connected 
in  series,  in  parallel,  or  in  a  combination  of 
both.  

o

  In the case of series connection, the Voc is 

the  relevant  value  when  calculating  the 
total voltage of the series connection.  Do 
not exceed the maximum system voltage of 
1000 V for the modules FU XXX P and FU 
XXX M even at low temperatures. Always 
use the same type and rating of module in 
one installation! 

o

  In  the  case  of  parallel  connection  of 

modules  or  series  strings  of  modules, 
fusing may be required.  

 

  The voltage of the strings of modules, in series, 

when measured at their poles, is the sum of all 
the  individual  voltages  of  each  module.  This 
total  voltage  should  be  compatible  with  the 
range  of  input  voltages  admissible  for  the 
inverter to which the modules are connected. 

 

Summary of Contents for FU M Series

Page 1: ...Author FuturaSun Document name Installation_manual_FuturaSun_2017 Revision date 07 08 2017 SAFETY AND INSTALLATION MANUAL Photovoltaic Module FU XXX P M...

Page 2: ...notice CONTENTS 1 General Information 3 2 Disclaimer of Liability 4 3 IEC 61215 61730 certifications 4 4 Limited Warranty 4 5 Module Specification 4 6 Safety Precautions 4 7 Installation 5 8 Use and...

Page 3: ...maximum power Impp Power Pmax with tolerance of 3 Solar radiation in W m2 at the time Temperature of the modules The general performance of the modules is heavily dependent on the intensity of the inc...

Page 4: ...allic jewelry and use insulated tools during installation Do not expose the modules to artificially concentrated sunlight Do not stand on drop scratch or allow objects to fall on the modules Do not li...

Page 5: ...on continuous base structures inclined or horizontal such as rails or similar Both base structures must be mounted at the same distance from the symmetrical axis vertical or horizontal of the module I...

Page 6: ...he mounting holes the drainage holes and the ground connection holes See the table of 60 and 72 cell module Mechanical drawing 60 cell module Mechanical drawing 72 cell module 7b Handling of Modules T...

Page 7: ...PV module is likely to experience conditions that produce more current and or voltage than reported at STC Accordingly the values of Isc and Voc marked on the module should be multiplied by a factor...

Page 8: ...will be approximately equal to Vocmod VocSTC Tmod 25 C x 0 125V Where o VocSTC is the open circuit voltage measured at STC o 0 125V C is the average variation of Voc of a module for a variation in tem...

Page 9: ...tion from mechanical stresses 9b How to Manage the Packaging Each package has been designed to allow the shipment and storage of modules in order to maintain their integrity unchanged over time provid...

Page 10: ...t During the handling of the pallet make sure to pay the utmost attention The packaging must be raised moved exclusively with fork lift trucks or hand pallet trucks fitted with forks of length appropr...

Page 11: ...isions without further notice 10 Temperature coefficients Technical data FU XXX P FU XXX M Voc temperature coefficient C 0 285 0 273 Isc temperature coefficient C 0 0474 0 0344 Pmax temperature coeffi...

Reviews: