background image

13 

FuturaSun srl – The specifications in this manual are subject to revisions without further notice 
This document applies to the module series FU XXX M ZEBRA 

FROM MANAGEMENT OF THE PACKAGING 
THAT IS IMPROPER OR DIFFERENT FROM 
WHAT WAS STATED IN THIS DOCUMENT. 

9d) Unpacking  

 
Observe  the  following  procedures  for  the 
unpacking of modules: 

  Place  the  packaging  on  a  stable  and 

flat surface  

  Using  a  cutter,  cut  the  plastic  wrap 

surrounding  the  package  or  to  open 
the paper box  

  Remove the plastic wrap  

  Remove the upper cover  

  Recover  the  flash  list  (for  record 

keeping) 

  Using a cutter, cut the straps  

  Remove  the  PV  modules  and  their 

protective corners without damaging 

 
Note: avoid storing partial packaging! 
Once  you  have  removed  the  strapping  the 
packaging must no longer be moved!!

 

Summary of Contents for FU M ZEBRA Series

Page 1: ...Author FuturaSun Document name Installation_manual_FuturaSun_2020 Revision date 01 09 2020 SAFETY AND INSTALLATION MANUAL Photovoltaic Modules FU XXX M ZEBRA...

Page 2: ...cument applies to the module series FU XXX M ZEBRA CONTENTS 1 General Information 3 2 Disclaimer of Liability 4 3 IEC 61215 61730 certifications 4 4 Limited Warranty 4 5 Module Specification 4 6 Safet...

Page 3: ...current as snapshots which enable you to monitor the operation of the modules and determine possible although rare anomalies The electrical output parameters for FU modules of technical importance dur...

Page 4: ...dards cover flat plate PV modules and panels intended for installation on buildings or those intended to be freestanding This product is not intended for use where artificially concentrated sunlight i...

Page 5: ...constitute an increased risk of electric shock and may cause injury or death Modules shall not be connected in series to create strings with a higher voltage than the maximum system design voltage and...

Page 6: ...load and 2400 Pascal 3600 including a safety factor of 1 5 wind load when the module is fixed in the green area See Fig 4 and following The FU XXX M ZEBRA modules regardless of half cut cell configur...

Page 7: ...ion with half cut cells the yellow areas allow for a typical load of 2400 1600 Pa 3600 2400 Pa maximum including 1 5 safety factor The red areas are not allowed for clamping and fixing Fig 5 Mechanica...

Page 8: ...ZEBRA 132 half cut cells Color min max Green 1 355 555 Yellow 1 0 728 Red 1 728 1092 Yellow 2 0 149 Red 2 149 847 1 on long side of frame 2 on short side of frame tolerance 2 mm Fig 7 Mechanical drawi...

Page 9: ...main power supply may only be performed by authorized and qualified persons Before connection of the system to the grid the PV system must be approved for correct installation by an electrician respon...

Page 10: ...the Voc and Isc When the PV modules are instead connected in series parallel configuration to an inverter from its display it is possible to read Operational voltage at maximum power output Vmpp of th...

Page 11: ...rves to identify anomalies The maximum module configuration when connected in series is 21 modules size 120 half cut cells for 1000 V DC systems The maximum module configuration when connected in seri...

Page 12: ...he connectors degrading the characteristics and altering the electrical properties of the contacts of the module causing damage DO NOT OVERTURN THE PACKAGING the packaging is only designed to be handl...

Page 13: ...following procedures for the unpacking of modules Place the packaging on a stable and flat surface Using a cutter cut the plastic wrap surrounding the package or to open the paper box Remove the plas...

Reviews: