Installation: 

Stage  5 

Page 9 of 18 // email info@futureautomation.co.uk  tel: +44 (0) 1438 833577  fax: +44 (0) 1438 833565

CHS - Ceiling Hinge & Swivel

Running screen cables

The mechanism has cable management through the pivot tube. Screen cables can be run
in at one end of the pivot tube and exit through a slot in its middle to go straight to the back
of the screen being mounted

The control box needs to be stored in an easily accessible location

CHS Mechanism
Cable Route

CHST Mechanism
Cable Route

Option 1 installation - Mechanism
will be in the ceiling as shown when
routing the cables. 
Option 2 installation -  Cable routing
can be done while the mechanism
is out on the floor.

Summary of Contents for CHS 3

Page 1: ...llationInstructions CHS CHTS CeilingHinge Swivel CeilingHinge SwivelwithTelescope Models CHS CHST3 4 5 Design Highlights Near Silent Motor System Bi Directional Swivel Unit Modular Format Ensures Simp...

Page 2: ...result in serious personal injury or damage to equipment Future Sound Vision trading as Future Automation intend to make this and all documentation as accurate as possible However Future Automation ma...

Page 3: ...ation Option 1 5 Stage 2 Installation Option 2 6 Deciding Which Way To Fix The Mechanism 6 Stage 3 Mechanism Installation 7 Stage 4 Securing The Mechanism 8 Stage 5 Running Screen Cables 9 Stage 6 Fix...

Page 4: ...ge 3 of 18 email info futureautomation co uk tel 44 0 1438 833577 fax 44 0 1438 833565 CHS CeilingHinge Swivel Tool Indicator Icons 1 2 3 4 5 6 1 Drill 3 Allen Keys 5 Screwdrivers 7 Pencil 2 Tape meas...

Page 5: ...2 Top Trim 1 3 Left Trim 1 4 Right Trim 1 5 Main Tray 1 6 Cross Bars 1 7 Screen Uprights 1 8 Pivot Tube 1 9 Mount Plates 1 10 Back Tary 2 Control Box 3 IR Remote Control Not Shown On Page 4 x2 AAA Ba...

Page 6: ...lowing The product is in good condition No damage to any parts Wiring is all secure The unit is in the closed position Test the mechanism by running it up and down best done with it upside down on the...

Page 7: ...unt Plates and mount in the correct place within the enclosure as shown to the left See next page for location details Mount plates Box removal Open mechanism to roughly 20 degrees undo all the bolts...

Page 8: ...7 fax 44 0 1438 833565 CHS CeilingHinge Swivel Fix the mount plates in the positions shown 27mm behind the back of the opening 22mm above the bottom of the finished ceiling level Option 2 Section CC 1...

Page 9: ...lift the mechanism into place and slide apart to lock in place 4 no M8 bolts need loosening so that the mechanism can telescope in and fit into the recess Then telescope out and tighten the bolts to s...

Page 10: ...n be run in at one end of the pivot tube and exit through a slot in its middle to go straight to the back of the screen being mounted The control box needs to be stored in an easily accessible locatio...

Page 11: ...ation Stage 6 Approx Set the screen frame at about 20 degrees from the up position The box can then be lifted into place When in place secure with the row of 4 bolts along the back M5x25mm and 2 M8 bo...

Page 12: ...the back of the screen Fixing the screen The screen can then be hooked on to the bars and retaining collars can be fitted to secure the screen Operate the mechanism with caution once the screen is in...

Page 13: ...r panel doesn t line up The closing position can be adjusted with the adjusting nut behind the left trim panel Take the mechanism up and down and adjust until flush when up Finally fix the left trim p...

Page 14: ...utureautomation co uk tel 44 0 1438 833577 fax 44 0 1438 833565 CHS CeilingHinge Swivel Connections Control Box Transformer IEC Power lead 110V 240V AC Connect infrared sensor here Connect the control...

Page 15: ...is in motion will stop the movement and all other contact closure commands will be disabled for 1 second 568A 568B 1 12V SUPPLY 12V SUPPLY CURRENT LIMITED W G W O 2 PIN 2 NOT USED G O 3 GROUND GROUND...

Page 16: ...g Carriage Return Enter ASCII 13 RJ25 9 PIN D PIN 1 RX TO PIN 2 TX PIN 6 TX TO PIN 3 RX PIN 3 GROUND TO PIN 5 GROUND PIN 4 GROUND TO PIN 5 GROUND PROTOCOL ACTION fa_in Carriage Return Enter Device IN...

Page 17: ...s into learnt position Store Programs current screen location to learnt positions see below Home Takes screen to forward facing position from an angled position Rotates screen left Rotates screen righ...

Page 18: ...fax 44 0 1438 833565 CHS CeilingHinge Swivel For information on our products please refer to our web site www futureautomation co uk or for questions on installations and our product range please phon...

Page 19: ...Page 18 of 18 email info futureautomation co uk tel 44 0 1438 833577 fax 44 0 1438 833565 Notes CHS CeilingHinge Swivel Notes...

Page 20: ...e Automation Unit 2 Kimpton Enterprise Park Claggy Road Kimpton Hertfordshire SG4 8HP United Kingdom Tel 44 0 1438 833 577 Fax 44 0 1438 833 565 Email info futureautomation co uk www futureautomation...