background image

Warning Symbol

Warning Symbol

Use the Manual

Use the Manual

This

Symbol calls attention to an operating procedure, practice, or

the like, which, if not correctly performed or adhered to, could result

in personal injury or damage to or destruction of part or all of the

product and system. Do NOT proceed beyond a warning symbol

until the indicated conditions are fully understood and met.

Specifications
Wiring
Programming

Page 3
Page 4
Page 5

NOTE:

It is strongly recommended that a process should

incorporate a LIMIT like L91 which will shut down the

equipment at a preset process condition in order

to preclude possible damage to products or

system.

It is strongly recommended that a process should

incorporate a LIMIT like L91 which will shut down the

equipment at a preset process condition in order

to preclude possible damage to products or

system.

Copyright a August 2001, Future Design Controls, all rights

reserved. No part of this publication may be reproduced,

transmitted, transcribed or stored in a retrieval system, or

translated into any language in any form by any means without

the written permission of Future Design Controls.

UM9090Rev1

2

Summary of Contents for FDC-9090

Page 1: ...User s Manual User s Manual FDC 9090 Self Tune Fuzzy PID Process Temperature Controller FDC 9090 Self Tune Fuzzy PID Process Temperature Controller ...

Page 2: ...hat a process should incorporate a LIMIT like L91 which will shut down the equipment at a preset process condition in order to preclude possible damage to products or system It is strongly recommended that a process should incorporate a LIMIT like L91 which will shut down the equipment at a preset process condition in order to preclude possible damage to products or system Copyright a August 2001 ...

Page 3: ...DESCRIPTION 4 INPUT RANGE ACCURACY 5 SPECIFICATIONS 6 INSTALLATION 8 OPERATION 7 CALIBRATION 7 CALIBRATION 8 OPERATION 8 1 KEYPAD OPERATION 8 2 FLOW CHART 8 3 PARAMETER DESCRIPTION 8 4 AUTOMATIC TUNING 8 5 MANUAL P I D ADJUSTMENT 8 6 MANUAL TUNING PROCEDURE 8 7 RAMP DWELL 6 1 DIMENSIONS PANEL CUTOUT 6 2 WIRING DIAGRAM 9 ERROR MESSAGES 9 ERROR MESSAGES In addition this instrument has functions of s...

Page 4: ...alibration data is lost you will need to return the controller to your supplier who may apply a charge for re calibration Note Do not proceed through this section unless their is a genuine need to re calibrate the controller All previous calibration date will be lost Do not attempt re calibration unless you have available appropriate calibration equipment If calibration data is lost you will need ...

Page 5: ...al parameters to be accessible at level 0 security 0 0 0 C B 10 C B 120 sec 30 sec 1 Proportional Cycle Time 0 to 120 seconds Relay Pulsed Voltage Linear Volt mA 20 1 0 Input Mode Selection 0 J type T C 1 K type T C 2 T type T C 3 E type T C 4 B type T C 5 R type T C Note T C Close solder gap G5 RTD Open G5 6 S type T C 7 N type T C 8 PT100 DIN 9 PT100 JIS 10 Linear Voltage or Current Alarm Mode S...

Page 6: ...easure the period of steady cycling PV PV Process value Tc TIME Record this value Tc in seconds Step 5 The Control Settings are determined as follows Proportion Band PB 1 7 Pc Integral Time TI 0 5 Tc Derivative Time TD 0 125 Tc 25 50 75 100 125 150 0 10 20 30 40 50 60 70 80 90 15 minutes ON OFF Process Value Alarm Output t minutes The dwell function may be used to operate an external device such a...

Page 7: ... limited to replacement or repair free of charge or refund of purchase price within the warranty period specified This warranty does not apply to damage resulting from transportation alteration misuse or abuse Future Design Controls warranties or representations of any sort regarding the fitness for use or the application of its products by the Purchaser The selection application or use of Future ...

Reviews: