TDX 9110N

TDX6 Temperature Scanner/Pyrometer

Installation and Operation Instructions

The TDX6 is an advanced design 6-point temperature 

scanner and pyrometer. It continually scans six 
grounded

tt 

 or ungrounded thermocouples, displays 

the temperature of the thermocouple selected and has 
adjustable trip points for each input. A trip point read/
scan knob provides for display and check/adjustment of 
the thermocouple temperature trip point. If any trip point 
is reached, its output turns ON and can be used as a 
control signal or to initiate alarms and/or shutdown.

Specifications

Power Requirements (Operating Voltages):

 120 VAC or 80-250 VDC, 

CD ignition or 24 VDC 

Outputs: 

Models TDX6-B and TDX6-D:

 

Six (6) isolated Field-Effect Transistor (F.E.T.) outputs; 0.1 A@ 250 VDC; 

switches on (applies ground) above trip point and switches off (removes 
ground) below trip point

Operating Temperature:

 -4 to 158° F (-20 to 70° C) 

Storage Temperature: 

-40 to 300° F (-40 to l50° C)  

Case:

 ABS 1/4 DIN (90 x 90 mm)  

Scanning Speed:

 Complete scan in 30 seconds  

Reset Differential:

 

F.E.T. Models:

 Decreases 3° F or (C)  

Display Update Time:

 Updates temperature every 0.3 seconds

Start-up Time Delay:

 Unit is locked out for 10 seconds after ignition 

voltage is sensed  

Ambient Cold Junction Compensation Range:

2° F from 32° F to 122° F (1° C from 0° C to  50° C )

Measurement Range:

 Monitor Range 0-1999° F or (C)

Accuracy:

 

With J-type thermocouple:

 from 50-150° F (J0-66° C) +3° F ( +2° C), 

from 150-1200° F (66-649° C) ±1.0% of reading  

With K-type thermocouple:

 from 400-2000° F (204-1076° C) ±1.0% of 

reading 

Trip Point Accuracy:

 ±3° F (±2° C) of reading 

Trip Point Adjustment Range:

 0-1999 Degrees 

Open Thermocouple Input:

 A number 1 appears in the display to the 

right of the channel number and the trip point operates

TDX6 Interface Capabilities

Model

Power Source

Rating

LCDT

CD Ign., 120 VAC, 12/24 VDC C

C1.I, Div.1, Gr. D, Haz. areas*

S5101

120 VAC, 12/24 VDC

C1.I, Div.1, Gr. D, Haz. areas*

TTD

CD Ign., negative ground, 12/24 VDC

C1.1, Div.2, Gr. D, Haz. areas**

TATTLETALE

®

CD Ign., 120 VAC, 12/24 VDC

Non-Hazardous areas

PLC’s and various annunciators not listed, contact factory

*

 An isolation barrier is needed between the TDX6 and an Annunciator rated for Class I, Division I, Group D, Hazardous Areas.

**

 

When used with approved ignition. Contact FW Murphy Production Controls for details.

t

 When power requirements are used as stated in Specifications section.

tt

 

Using grounded thermocouples introduces the risk of odd currents or voltages being imposed on the thermocouple signal which can affect the accuracy of the reading. This is 

an inherent problem of grounded thermocouples, and the reason why we prefer unground ed thermocouples.

Description

Dimension

Before beginning installation of this product:
• 

Disconnect all electrical power to the machine

• 

Make sure the machine cannot operate during installation

• 

Follow all safety warnings of the machine manufacturer

• 

Read and follow all installation instructions

Please read the following instructions and warnings before installation. Visually inspect the product for any damage that may have occurred 
during shipping. It is your responsibility to have a qualified person install this unit and make sure it conforms to NEC and local codes.

t

Reviews: