FXO H.323 Gateway User Manual
Document Ver.: 118a
Release Sep, 2004
88
-faxrdd
set fax redundancy depth. User can increase FAX
redundancy depth when network traffic is heavy. For
example, if user set fax redundancy as 2, Gateway will
resend fax packets every 2 packets.
-fstart
to switch ON/OFF (1 = ON; 0 = OFF) fstartStart function.
Fast Start function can shorten the connection time if the
opposite party also supports fastStart.
-tunnel
to switch ON/OFF (1 = ON; 0 = OFF) H.245 tunneling
function. If the function is ON, Gateway will send H.245
(Call Control messages) via H.225’s (Call Signal messages)
link. The function is effective only when both sides support
H.245 tunnel.
-h245fs
If the function is ON, Gateway can send H.245 messages
after FastStart.
-earlyh245
enable/disable early H.245 function. The function is
effective only when both sides support early H.245.
Note: it is not recommended to change the value in this command, only if
users do know well the application. This might cause incompatibility
with other devices.
4.2.17 [sysinfo]
Show the status of the port and registrations
-------------------------------------------------------------------------------------------------
usr/config$ sysinfo
System information
Index Registration Status
===========================
1 OK Ready
2 OK Ready
3 OK Ready
4 OK Ready
usr/config$