background image

28

29

Capacity Cut-Off
ON        5000mAH

Key Beep      ON
Buzzer        ON

Capacity 

Current 

Safety Time

2000mAh 

2.0A 

(2000/2.0=1000)/11.9=84 minutes

3300mAh 

3.0A 

(3300/3.0=1100)/11.9=92 minutes

1000mAh 

1.2A 

(1000/1.2=833)/11.9=70 minutes

For example:

This program sets the maximum charge capacity 
that will be supplied to the battery during charge. 
If  the  deltapack  voltage  is  not  detected  nor  the 
safety  timer  expired  by  any  reason,  this  feature 
will automatically stop the process at the selected 
capacity value.

The  beep  sounds  at  every  time  pressing  the 
buttons  to  confirm  your  action.  The  beep  or 
melody  sounded  at  various  times  during 
operation to alert different mode changes.
These audible sounds can be on or off.

Input Power Low
Cut-Off    11.0V

This  program  monitors  the  voltage  of  input 
battery.  If  the  voltage  drops  below  the  value  you 
set  the  operation  forcibly  terminated  to  protect 
the input battery.

Ext. Temp    0C
Int. Temp   37C

This screen shows the external and internal
temperature.

11.9, set this number as the value for safety timer 
setting.  If  the  charger  stopped  at  this  threshold, 
about 140% of the capacity will have been fed into 
the battery.

SYSTEM SET UP

VARIOUS INFORMATION DURING THE PROCESS

VERSION
            1.00

LOAD FACTORY SET
           ENTER

Press and hold the Start/Enter button for more than 
three seconds to load the factory set.

This screen shows the version. 

You  can  inquire  various  information  on  LCD  screen  during  charging  or 
discharging  process.  When  you  press        button  the  charger  shows  the 
establishment of user settings.
And also you can monitor the voltage of individual cell by pressing      button 
when  the  individual  connection  cable  is  linked  to  the  Lithium  battery  being 
processed.

Ext. Temp    0C
Int. Temp   26C

It comes to the final voltage when the program
ended. 

Present input voltage. 

This screen shows the internal temperature.

Displayed safety timer is turn on and duration of time in 
minutes.

Displayed capacity cut-off function is turn on and the 
setting value of capacity.

The battery is connected with balance lead, you can 
check voltage of each cell in the battery pack. 

VARIOUS INFORMATION DURING THE PROCESS

4.19  4.15  4.18V
0.00  0.00  0.00V

Summary of Contents for G6

Page 1: ...Balance Charger Discharger Ver 1 30 INSTRUCTION MANUAL Products by G FORCE Inc www gforce hobby jp Mare kanda Bld 9F 1 3 1 Kajicho Chiyoda ku Tokyo 101 0044 JAPAN Copyright 2014 G FORCE Inc All Right...

Page 2: ...lead Pb batteries are charged using the CC CV method The fan cooling system is so smart and efficient The fan speed is controlled by internal temperature sensor The user can check battery s total volt...

Page 3: ...ancing Individual Cells Battery Discharging During the process of discharging can monitor and balance each cell of the battery individually Error message will be indicated and the process will be ende...

Page 4: ...e principle of the Delta peak voltage detection When the battery s voltage exceeds the threshold the process will be terminated automatically SPECIAL FEATURES Automatic Charging Current Limit You can...

Page 5: ...al charge circuit or a protection circuit A battery pack which consists of different types of cells including different manufacturers A battery that is already fully charged or just slightly discharge...

Page 6: ...the battery s capacity is calculated by multiplying single the battery s capacity by the number of cells bearing in mind that total voltage stays the same If the voltage is imbalanced it may cause a f...

Page 7: ...the charger first and only then to the battery Reverse the sequence when disconnecting the pack Balance socket The balance wire attached to the battery must be connected to the charger with the black...

Page 8: ...T VOLTS 4 0V 2S CHARGE CURRENT 3 3A DSCH CURRENT 1 5A DSCH VOLTAGE 1 7V CELL SAVE PROGRAM ENTER PROGRAM SELECT Pb BATT ENTER START Pb CHARGE 2 0A 2 0V 1P Pb DISCHARGE 0 1A 2 0V 1P PROGRAM SELECT Ni C...

Page 9: ...tteries with a balance lead in the balance mode only The left side of the first line shows the type of battery you choose The value on the left of the second line of the charger is current user set Af...

Page 10: ...l you can start charging by press Start Enter button If LITHIUM BATTERY LiPo LiFe LiIon PROGRAM Start Enter Current voltage battery Supplied capacity Charge current Charging time Number of cells not p...

Page 11: ...key to make it blink then change the value using or key The value will be stored by pressing Start Enter key once To start the process press Start Enter button for more than 3 seconds CHARGING OF BAT...

Page 12: ...ts the end of discharging Elapsed time Charged capacity Battery type Charge current Battery voltage NiMH RE PEAK 1 NiMH 2 0A 9 59V RPC 000 33 00017 Re peak cycle 1 shows on the display Press the Start...

Page 13: ...d of process DISCHARGING OF PB BA TTER Y Set discharge current on the left and final voltage on the right The discharge current ranges from 0 1 to 2 0A To start the process press Start Enter key for m...

Page 14: ...0 1A 2 0A Set the discharge voltage which can be adjusted 3 0V CELL 3 3V CELL Set the voltage and number of cells along with the normal voltage 1 6S Set the charge current which can be adjusted 0 1 10...

Page 15: ...N 120Min User set up starting screen The battery is on the cyclic process of charge and discharge can often become warm after charge or discharge period The program can insert a time delay to occur af...

Page 16: ...re 11 9 set this number as the value for safety timer setting If the charger stopped at this threshold about 140 of the capacity will have been fed into the battery SYSTEM SET UP VARIOUS INFORMATION D...

Page 17: ...TAGE INVALID Voltage of one cell in the battery pack is invalid The external temperature of the unit goes too high EXT TEMP TOO HI OVER CHARGE CAPACITY LIMIT The battery capacity is more than the maxi...

Page 18: ...employ for using operating and maintaining the device For this reason we are obliged to deny all liability for loss damage or costs which are incurred due to the incompetent or incorrect use and oper...