SL DC2 Setting Automatic Close Operation
Refer to the “
SL DC2 Circuit Board”
data sheet included with this manual and locate the ‘AUTO
CLOSE ’ settings on the circuit board.
The gate motor is supplied with the Auto Close OFF as standard.
The gate motor can be set to ‘Auto Close’ by simply flicking DIP switch 1 to ON, press and hold
down “OSC” button for the required time you want the gate to remain open before it auto closes,
and release the button. For example if you want the gate to remain open for 30 seconds before it
auto closes then press and hold down the “OSC” button for 30 seconds and release the button.
Once time is set flick DIP switch 1 back to OFF.
To start the Auto Close function flick DIP switch 8 to ON and leave it on. To disable the Auto
Close flick DIP switch 8 back to OFF.
To adjust the Auto Close hold open time repeat these instructions.
WARNING
If the ‘Auto Close’ feature is enabled, then precautions should be taken to
ensure the gate can close without hitting any obstructions or suitable safety
accessories are also installed.
Regularly check that all safety features and safety accessories are fully
functioning.
SL DC2 GATE MOTOR
INSTALLATION AND SET UP
INSTRUCTIONS
Flick DIP switch 8 to ON to start Auto Close
or back to OFF to disable Auto Close
Flick DIP switch 1 to ON and press
“OSC” to set the Auto Close time.
Flick back to OFF when finished.