background image

15

F0 00 20 71 14 01 00 ...

 - message in this format is interpreted as memory content. If controller is set on

mode enabling to receive this message the data will be received and the whole preset and setup memory

will be overwritten.

MIDI output (MIDI OUT)

Every of 100 presets can send one Control Change and three Program Change commands. For Control

Change command the controller’s number is common for all the presets. Commands are sent each time

after selecting the preset. Successively are sent Program Change 3, Program Change 2, Program Change

1 and Control Change commands.

System Exclusive dump memory message specification

Controller attend one SysEx type message containing presets and setup memory data (memory dump). It

enables to save memory backups and editing presets and setup on the computer. It is possible to copy the

memory from one to another MGC. Sending out the memory contain can be recalled manually in 

bdp

function (in controller’s SETUP) or remotely by MIDI request message.

Memory contain message specification:

1)

First byte 0xF0 - SysEx Start

2)

Three bytes G LAB ID ( 0x00 0x20 0x71)

3)

SysEx message channel (14h)

4)

One byte device ID MGC-6 1.xx (01h)

5)

Message statute byte (00h – data to store)

6)

101 frames with memory contain

MIDI specification is expected to send data with cleared eighth bite. Because of that the data is packed in

eight or three data bytes in given way: seven bytes with MSB=0 + eighth with MSBs or two bytes + third as

on the scheme below.

Memory frame containing 16 bytes is sent as a frame with 8+8+3 MIDI data bytes.

First frame contains the general information about the controller and its setup in following order:

a)

3 data signature bytes (03h , 05h , 09h)

b)

1 reserved data byte

c)

1 data byte with the input channel number (range 1-16)

d)

1 data byte with the output channel number for the Program Change 1 (range 1-16)

Summary of Contents for MIDI Guitar Controller

Page 1: ...Instrukcja obs ugi User Manual Bedienungsanleitung MGC 6 Guitar Controller Midi...

Page 2: ......

Page 3: ...mand ___________ 9 CC Controller s number programming ___________________________________ 10 MIDI OUTPUT mode programming_______________________________________ 10 Bulk memory dump ___________________...

Page 4: ...presets programming and copying To avoid accidental presets changing controller posses the six level memory protection Basic features true passive signal path true bypassed by electro mechanical rela...

Page 5: ...digit 4 of the numeric keyboard in Fun mode MEM PROT memory access lock switch RETURN effect loop input connector 6 AUX 5 output switch or 16 LOOP 2 switch or in Fun mode SETUP switch SEND effect loo...

Page 6: ...4 Diagram of devices connectable to the MGC 6...

Page 7: ...parasitic capacitance appearing when all the effects are switched off SEND outputs should be connected with IN effects inputs and RETURN inputs should be connected with OUTPUTs of particular effects...

Page 8: ...l of AUX output Lighting of the decimal point after the P letter means that actual preset was modified MIDI program numbers programming MGC 6 enables to control three MIDI devices separately on differ...

Page 9: ...e memory protection Preset s copying Controller enables to copy the whole preset The procedure is similar to preset s saving Selecting the preset No to copy as well as storing could be done by the use...

Page 10: ...m Change 3 channel number Co4 Control Change channel number Cno CC Controller s number nio MIDI output mode bdP Bulk memory dump rdP Memory dump permission CEE Clearing of the presets memory MIDI INPU...

Page 11: ...s The available range is from 1 to 16 Displaying of the r letter with the channel number means that the number of this channel is already reserved r for other Program Change command Example below show...

Page 12: ...ke controller s memory backup Sending and receiving System Exclusive dump memory message enables editing the presets and setups on the computer Sending the System Exclusive dump memory message is only...

Page 13: ...ction have to be done using mono or stereo Jack Jack cable Y type cable stereo Jack 2 x mono Jack or need dedicated cable or adapter offered by G LAB The actual list of available cables and adapters y...

Page 14: ...C by two effect loops Two stereo effects switch TRUE BYPASS AUX A B SWITCH connection AUX A B SWITCH enables switching two different signal sources to one OUTPUT Connection of the devices should be do...

Page 15: ...Program number Function 0 99 1 100 Preset number 100 101 mute ON Control Change Controller s number Controller s value Function 0 63 AUX1 switching off 20 64 127 AUX1 switching on 0 63 AUX2 switching...

Page 16: ...3 switching on 0 63 LOOP4 switching off 55 64 127 LOOP4 switching on 0 63 LOOP5 switching off 56 64 127 LOOP5 switching on 0 63 LOOP6 switching off 57 64 127 LOOP6 switching on 0 63 BUFFER switching o...

Page 17: ...py the memory from one to another MGC Sending out the memory contain can be recalled manually in bdp function in controller s SETUP or remotely by MIDI request message Memory contain message specifica...

Page 18: ...RY 8 b 1 byte with the information about the SWITCH OUTPUTs state according to the scheme below S1 S4 SWITCH 1 SWITCH 4 X reserved c 1 byte with the information about the LOOPs state according to the...

Page 19: ...ange 0 127 7 20 31 52 61 Prog Change 1 128 1 101 System Excl O O System Common Song Pos X X Song Sel X X Tune X X System real time Clock X X Commands X X Aux Messages Local ON OFF X X All Notes OFF X...

Page 20: ...18...

Page 21: ...vice into an outlet on a circuit different from that to which the receiver is connected Contact with the manufacturer see Before calling a service Consult the dealer for help Certificate of Conformity...

Page 22: ...ment Parties collecting such equipment organise a system including local collection points shops and other units allowing to return such equipment This Directive assures an user free of charge utilisa...

Page 23: ......

Page 24: ...d phone 48 32 272 20 21 fax 48 32 272 81 90 Web site www glab com pl Export Department phone 48 32 272 30 51 inter 34 48 32 272 20 21 inter 366 e mail rydygier elzab com pl Technical Support phone 48...

Reviews: