DIMMER-SHUTTER-STROBE 

 

0 – 100% mechanical linear dimming (adjustable from full blanking to full 
opening effects). 
1-7 flashes/second ultra high speed strobe effect. 

 
 

PAN TILT 

 

Horizontal direction 540° scanning, smooth scanning action and accurate 
orientation. 
Vertical 250° scanning, smooth scanning action and accurate orientation. 
Pan/Tilt lock. 
Pan/Tilt w 8/16 bit resolution. 
Automatic Pan/Tilt repositioning. 
Precise adjustment on horizontal and vertical position. 
Precise speed adjustment on horizontal and vertical position. 

 
 

INPUT 

 

3 pin or 5 pin in and out DMX 512 signal. 
18 Channel (16 Bit) or 12 Channel (8 Bit). 

 
 

SET UP 

 

Separate motor debug remote control.  
Separate DMX address functions remote control: stand, inverted, light on, 
light off. 
Auto test all functions. 
Display “flip” function 180° rotation. 
Working temperature adjustment. 

 

 
POWER 

 

Magnetic Ballast Version. 
200V -220 V – 60 Hz. 
100V -120 V – 60 Hz (optional). 
220V -240 V – 50 Hz (optional). 

 

Built-in over heat protection and high voltage protection. 
PFC power factor compensation. 
According to various kinds of safety standards, IP20 protect grades, the 
cable accords to CE20/22 standard. 

Summary of Contents for 600SZ

Page 1: ...www g lites com 1 User Manual MOVING HEAD MODEL 600SZ ...

Page 2: ...ply connection control 11 4 2 signal connection 11 4 3 Fixture connection 12 5 Moving Head IP Code Programming 12 6 Moving Head IP Function selection 13 7 Display Menu Map 13 8 DMX Channels Photometrics 8 1 Channel Table 15 8 2 DMX Protocol Chart 16 9 Luminosity intensity 19 10 GOBO an GOBO Size 19 Maintenance 20 Technical Data 21 Troubleshooting 23 ...

Page 3: ... the safety precautions listed below A Read this manual carefully and keep manual near moving head B Follow the safety regulations mentioned in this manual when operating or installing this fixture C Warranty is void if the product is misused damaged or modified in any way or for unauthorized repairs or parts D For maintenance or lamp replacement disconnect the fixture from main power before openi...

Page 4: ...www g lites com 4 ...

Page 5: ...mmitment to continuous products update the company will keep the right to improve this product the information in this menu may be changed without notice Transportation Please be sure to lock the head before transportation Cardboard box The cardboard box is not designed for repeated use and for transportation of the fixture we recommend the use of our fixture cases Single flight case The fixture c...

Page 6: ...www g lites com 6 ...

Page 7: ...d to the bottom of the moving head with 4 bolts provided in the package Always make sure that the moving head is anchored firmly to avoid any vibration or fall For safety purposes the moving head should be connected with the safety cable ends by looping the cable over the truss running it through the truss and the handle of the moving head The safety cable will fasten the moving head on the truss ...

Page 8: ...rface Keep flammable objects at least 1 meter away from fixture Do not light objects closer than 1 meter o Replace fuses only with the specified type and rating o Ambient temperature In order to ensure proper fixture operation the room temperature must be higher than 33 and no lower than 2 o Surface temperature Equipment surfaces may reach temperatures up to 100 C 212 F Allow 5 minutes for cooling...

Page 9: ... 5 total quantity of the moving head then you could get the minimum power loading If your power cable can t share the minimum power supply loading Do not connect all the moving heads 3 Lamp replacement Lamp Description Model Lamp Description Philips Osram 600SZ MSI 575W HR HMI 575W GS 6000 K 1000 Hr 5600K 1000 Hr Lamp Replacement Warning Disconnect the power supply before replacing the lights Open...

Page 10: ...re of the recharge lamp can not work under the interruption power supply Therefore please let the lamp cool down completely Approx 15 minutes at least Then it s ready to operate again Other wise it will lead to high tension short circuit or electric discharge It may cause the part of the control board to burn down Warning 4 All the lamps have its usage life please inspect the lamp timing and ensur...

Page 11: ...RAM and PHILLIPS is 700 hours the average lift time of other brand is 70 100 hours 4 Power Supply Control 4 1 Power Supply Connection and Control Use a professional plug to connect the moving head and main power supply Pay attention to the voltage frequency the same as mentioned on the moving head suggest each fixture has an independent switch of the power supply so that it can be turned on or off...

Page 12: ...ce of the fixtures is over 15meter 4 3 Fixture Connection After performing the above instructions and after making sure the moving heads have the appropriate lamps press the power switch to check whether everything is working normally The LED display will show the original DMX signal address The moving head has a reset function It means that if draw out the communicate cable or turn off the contro...

Page 13: ...r 1 DMX setting address setting d 001 d 512 2 PAN normal anticlockwise 180 degree setting Pa rI PA LE 3 TILT normal anticlockwise setting TI Dn TI Up 4 Extend compress channel setting 16 bit 8 bit 5 PAN TILT run speed setting total 1 10 level SPd 6 SPd 1 10 6 Lamp on controller turn on setting LAP y LAP n 7 Display normal inversion mode dIP P dIP A 8 Fixture working hours H000 9 Key press restorat...

Page 14: ...www g lites com 14 ...

Page 15: ...e 4 Pan Coarse 5 Tilt Coarse 5 Tilt Coarse 6 Color Wheel A 6 Color Wheel A 7 Gobo Wheel B 7 Gobo Wheel B 8 Gobo Wheel A 8 Gobo Wheel A 9 Gobo Wheel A Rotation 9 Gobo Wheel A Rotation 10 Iris 10 Iris 11 Focus 11 Focus 12 Zoom 12 Zoom 13 Prism Rotation 13 Prism Rotation 14 Color Wheel B 14 Color Wheel B 15 Blackout movement functions 15 Blackout movement functions 16 Pan Tilt Speed 16 Pan Tilt Speed...

Page 16: ...www g lites com 16 8 2 DMX PROTOCOL CHART ...

Page 17: ...www g lites com 17 ...

Page 18: ...www g lites com 18 ...

Page 19: ...etal GOBO Wheel A outside 28mm inside 22mm Rotating glass GOBO Wheel A outside 28mm inside 21 5mm Fixing GOBO Wheel B outside 28mm inside 20 5mm White outside 28mm inside 23mm The GOBOS can be different than the picture that you see in this manual the manufacturer has the right to make any adjustment without notice ...

Page 20: ...use it to explode If the lamp is accidentally touched clean it immediately with a soft cloth and isopropyl alcohol CH CH0H o Clean the lens and dichroic filters on a regular basis Do not use any type of solvent since it may damage the fixture just use a clean cloth It is not recommended to use the fixture for more than 4 hours Continuous use will shorten the life of the lamp o Clean your fixture o...

Page 21: ...LOR wheel GOBO 8 fixed interchangeable metal gobos white light 6 rotating glass gobos white light all can be custom made Rotating gobos can freely move clockwise or anticlockwise fast or slowly Angles for rotating gobos can be separately adjusted to ensure consistency of gobo orientation and angle EFFECTS 3 faces prism lens with free clockwise or counterclockwise rotation 13 32 stepless zooming fe...

Page 22: ...l position Precise speed adjustment on horizontal and vertical position INPUT 3 pin or 5 pin in and out DMX 512 signal 18 Channel 16 Bit or 12 Channel 8 Bit SET UP Separate motor debug remote control Separate DMX address functions remote control stand inverted light on light off Auto test all functions Display flip function 180 rotation Working temperature adjustment POWER Magnetic Ballast Version...

Page 23: ...www g lites com 23 CONSUMPTION Power Consumption 680 W DIMENSION L470mm W365mm H697mm WEIGHT 43 5 Kg ...

Page 24: ...t color o Replace the lamp o Clean optics o Re home the fixture Unit is producing unexpected results o Check DMX starting address on the fixture and console match o Verify that the last fixture on the link is terminated Unit is not responding to console o Verify that the fixture has the correct DMX address o Check and replace data cables o Verify that the last fixture on the link is terminated Uni...

Reviews: