background image

 

 

4

 
Adjust the center of light beam: the light beam adjust well or not is the hinge of the 
light effect. After finished the lamp installation, please do not stand in front of the 
lamp when the front cover was open. 
Switch on power the lamp will light up. And then make the light faces to a plane goal 
and check the light center whether is right or not. If need to adjust, you can turn the 
screw near the light beam to right or left to make the center of light beam at the right 
station.  
 
Adjustment of facula number: there has turner at the back cover of light. You can 
adjust the focus by turning it to right or left to meet your inquiry. Then the focus of 
facula to one parallel light beam, the light up distance is most far. When you use it as 
special light-set, you can adjust the focus as your inquiry. Pay more attention to that 
there has the black center of the light beam if your facula is too large. 
 
Light source is high voltage xenon lamp: Do not touch the ball part during the 
installation, to keep clean the ball and increase the light effect and life-span. Lamp 
must cool by strong wind during working. Must pay attention to the back fan whether 
works well or not always. 
 
Clean all optics lens and reflector at regular to increase the effect. Cleaning times 
according to the operate frequency and usage situation. We suggest  to clean the 
outside systems per 20 days a time and inside optics lens per 60 days. To keep 
luminous flux rate through clean the lamp with soft cloth or cotton stick dipped 
alcohol to wipe the mirrors. 
 
This light has the automatic scan system. If the lamp was working, and you want 
automatic scan and strengthen the light, it just switch on the motor-head the power 
console then the light will scan about 120° in the horizontal direction 3 times per 
minute. 
 
This light has 5 power switches, open one add 1000w, if open all the switches. That 
it’s the total power of the lamp. 
 
This lamp is automatic touch off, it will light on when connect power, if it doesn’t 
happen, please check as following: 
Test the voltage at the two sides of the lamp bulb first.  If there has no voltage or 
voltage not stable, it means that the power board has problems. If there has stable 
current up to 100V above in the two sides of the lamp bulb and trigger make fir all 
the time.  It means that the lamp bulb maybe has problems. If the trigger does not 

Summary of Contents for STAR SEARCH 4000

Page 1: ......

Page 2: ...iew It is very important to connect the earth line to earth Attention Do not separate the light by yourself Call technician in case the machine break down Set the light immobility and try to avoid strong shake or hit Prevent the dust into the product Make the vent pipe not be jammed while the light is working Check the power line whether be connected well before put on power Do not look at the lig...

Page 3: ...d connect well Must check the connect condition to avoid the resistance time Xenon lamp which higher than 2000w uses disassembly connect line Must use two spanners while install lamp One holds the copper gap Another turns the hexangular screw Any pressure or torsion not permitted Xenon ball lamp is super high voltage discharge lamp It must out of hit because there has high voltage before work and ...

Page 4: ...ol by strong wind during working Must pay attention to the back fan whether works well or not always Clean all optics lens and reflector at regular to increase the effect Cleaning times according to the operate frequency and usage situation We suggest to clean the outside systems per 20 days a time and inside optics lens per 60 days To keep luminous flux rate through clean the lamp with soft cloth...

Page 5: ...he end of xenon lamp cathode and then take off cathode line During take off then xenon lamp must hold the lamp in hand immobility Do not let the lamp fall down or make any ram otherwise the lamp will break up and influence the cleaning inside the lamp box Step4 Set the xenon lamp or the light head epoxy board and light head cover according to the contradictorily step Step5 Set the case of light he...

Page 6: ...2 18 24 and 28 light beams Light beam circles 80º 120º Range 1 5 Km Pan 110º Tilt 40º INGRESS PROTECTION IP44 POWER SUPPLY 4000W 220V AC optional 110V DIMENSIONS Physical dimension L25xW22xH49 inches L640xW560xH1240mm Gross dimension L35xW29xH57 inches L890xW740xH1450 mm WEIGHT Physical weight 66 Kg 145 Lb Gross weight in one flight case 116 Kg 255 Lb ...

Page 7: ...o explode If the lamp is accidentally touched clean it immediately with a soft cloth and isopropyl alcohol CH CH0H o Clean the lens and dichroic filters on a regular basis Do not use any type of solvent since it may damage the fixture just use a clean cloth It is not recommended to use the fixture for more than 4 hours Continuous use will shorten the life of the lamp o Clean your fixture on a regu...

Page 8: ...estrike Unit is producing unexpected results o Check DMX starting address on the fixture and console match o Verify that the last fixture on the link is terminated Unit is not responding to console o Verify that the fixture has the correct DMX address o Check and replace data cables o Verify that the last fixture on the link is terminated Unit is not moving o Check if the power supply is suitable ...