1. Connections

The connections of the stations must be made using CAT. 5e SF / UTP cables with braided shields and shielded STP con-
nectors. For these cables (and the associated RJ45 connectors), standards EIA/TIA T568A and EIA/TIA T568B call for the 
pinouts and colours indicated in the table. The pinouts of the IN / OUT connectors are also indicated (B). 

Attention!

 

Cross-cables are not permitted. All the connectors must be shielded RJ45 connector.

I

UK

CONNESSIONI

CONNECTIONS

2.1   Collegamenti delle postazioni

I collegamenti delle postazioni sono effettuati tramite cavi STP cat.5 
diretti (cioè non incrociati o ‘cross-cable’). Gli standard EIA/TIA 
T568A e EIA/TIA T568B prevedono per tali cavi (e relativi connettori 
tipo RJ45) le seguenti piedinature e colorazioni:

Importante! 

Tutti i connettori devono essere di tipo RJ45 schermato. 

Tutte le postazioni dispongono di due prese di ingresso/uscita  

IN/OUT 

(9). Nelle tabelle sottostanti vengono elencate le piedinature 

di questi connettori.

Le postazioni 

MBT 1106 

MBT 1112 

sono connesse tra loro in 

cascata, utilizzando le prese posteriori 

IN/OUT

 (

9

), come illustrato in 

Fig. 2.1.1; si fa presente che le due prese IN/OUT  possono essere 
utilizzate indifferentemente sia come ingresso che come uscita. 
Per il numero massimo di postazioni utilizzabili, fare riferimento 
al manuale dell’unità di controllo del sistema in cui le basi sono 
utilizzate.

1

2

3

4

5

6

7

8

Pin 1

Pin 8

8

7

6

5

4

3

2

1

Pin 8

Pin 1

T568A STANDARD

Pin

Colore

Colour

1

bianco/verde

white/green

2

verde

green

3

bianco/arancio

white/orange

4

blu

blue

5

bianco/blu

white/blue

6

arancio

orange

7

bianco/marrone

white/brown

8

marrone

brown

T568B STANDARD

Pin

Colore

Colour

1

bianco/arancio

white/orange

2

arancio

orange

3

bianco/verde

white/green

4

blu

blue

5

bianco/blu

white/blue

6

verde

green

7

bianco/marrone

white/brown

8

marrone

brown

Pin

IN/ OUT

1

Audio +

2

Audio -

3

GND

4

Non collegato / Not connected

5

Non collegato / Not connected

6

+Vcc

7

S /

8

Seriale – / Serial –

Schermo / Shield

GND

2.1   Connections of stations

The stations are connected by means of direct Cat. 5 STP cables 
(no cross-cables). In accordance with EIA/TIA standard T568A and 
EIA/TIA standard T568B, the pin-out for these cables (and their 
RJ45 connectors) and the colour codes are:

Important! 

All the connectors must be shielded RJ45 type. 

Each station has two 

IN/OUT 

(

9

) input/output sockets. The pin-outs 

of these connectors are listed below.

The 

MBT 1106 

and 

MBT 1112 

stations are connected to one another 

in cascade formation using the rear-panel 

IN/OUT

 sockets (

9

), as 

illustrated in Fig. 2.1.1. It is pointed out that the two IN/OUT sockets 
can be used either as inputs or as outputs as required. For the 
maximum number of stations that can be used, refer to the manual 
of the control unit of the system in which the bases are used. 

Fig. 2.1.1

Connection diagram T568B STANDARD:

Pin 

T568A (Colour)  

T568B (Colour)  

IN / OUT (Function)

1   

White / Green 

White / Orange 

Audio  +

Green 

Orange 

Audio –

White / Orange   

White / Green 

GND

4  

Blue 

Blue 

Not connected

5   

White / Blue 

White / Blue 

Not  connected

Orange  

Green 

+VDC

White / Brown 

White / Brown   

Serial  +

Brown 

Brown 

Serial –

Shield Shield 

Shield 

GND

1.1. Connection to compact system VA-500

The VA-FMCT-500 stations have to be connected to the EMG. DESK socket of the compact VA-500 system and used as 
alternatives to the emergency systems of the FMD range. There can be at most two stations in each card-cage. 

1.2. Sizing

Using a CAT 5e SF/UTP cable with braided shielding, the following maximum limits can be maintained for the total length of 
the connection:
1 station total length   max. 300 m
2 stations total length   max. 200 m

For systems with more than three stations connected to them, at distances greater than those indicated above, each station 
will also have a local power supply providing a continuous stabilised current of 24 VDC / 500 mA, using the socket provided 
for this purpose on the rear (A).

Summary of Contents for VA-FMCT-500

Page 1: ...lektronik ag will not accept any liability for damage to property and or persons arising out of incorrect use of the equipment or of procedures that do not comply with the instructions provided in thi...

Page 2: ...e brown T568 Pin Colore 1 bianco aranc 2 arancio 3 bianco verde 4 blu 5 bianco blu 6 verde 7 bianco marro 8 marrone Pin IN OUT 1 Audio 2 Audio 3 GND 4 Non collegato Not connected 5 Non collegato Not c...

Page 3: ...This indicates the presence of at least one zone in which the sending out of emergency messages is disabled BUSY yellow Off system free no station on calls Steady ON this indicates that another statio...

Page 4: ...di accesso al menu di con gurazione C Tastiera selezione zone D Indicatore di stato della chiamata a viva voce spento PTT non attivato acceso PTT attivato E Tasto per invio chiamata a viva voce PTT F...

Page 5: ...sting call hands free To send out a service message hands free to the broadcasting areas press the PTT button E and hold it down The green indicator will light up to show that the microphone is active...

Page 6: ...y under way activated by another station or by local commandsby the system Steady ON Manual emergency activated from the station itself All the keys are active so as to enable the operator to manage t...

Page 7: ...mergency with the EMERGENCY key all the keys turn green to indicate general pre selection press the buttons corresponding to the required zones These will remain green to con rm that they have been se...

Page 8: ...failures press the RESET ACK key briefly The buzzer will be muted only on the station while the LED referred to the failure under way will remain ON This function is active in any status of the stati...

Page 9: ...return to the main screen press Escape 4 1 Function key con guration This screen page enables the broadcasting zones to be associated with the function keys from F1 to F6 Using this option it will be...

Page 10: ...ey again and digit uf ci the wording Zone name uf ci will appear Press Enter to con rm 4 Press Save changes to save the con guration Continue in the same manner for the other keys UK TSC6000 EN 4 3 Le...

Page 11: ...if any of serial communication with the control unit to which the station is connected is also signalled on this page 3 4 Unit configuration This screen page enables the main operating parameters of...

Page 12: ...Filter 10 dB 100 Hz S N Ratio 60 dB Connection RJ45 IN OUT Power supply voltage 24 VCC Maximum absorption 24 VDC 165 mA Dimensions W H D 230 80 200 mm Net weight without microphone 1 6 kg Dimensions...

Reviews: