12. 

For Basic & 6D models

: To reverse the cleaning process, disconnect the pressure and return hoses 

        from the ATF cooler.  Now connect the pressure hose to the cooler 

inlet

 line and the return hose to the 

        cooler 

outlet

 line.  Cycle the motor toggle on and let the machine flush for 15 minutes.  Regulate the   

        air supply to 90-100 psi.  While the machine is running, open the air purge valve for 10-15 seconds.       

        Then close the air purge valve for 5 minutes.  Repeat the process 3 times. 

 

 

12a. 

For TTCF-7AR models

 

 

To reverse the cleaning process, simply turn the reverser lever to the opposite setting.  Cycle 

 

 

the motor toggle on and let the machine flush for 15 minutes.  Regulate the air supply to 90-

 

 

100 psi.  While the machine is running, open the air purge valve for 10-15 seconds.  Then 

 

 

close the air purge valve for 5 minutes.  Repeat the process 3 times.  

See Addendum 2

 for an 

 

 

explanation of the reverser. 

 

13.

 

Cycle off the motor toggle leaving the air purge valve open for at least 15 seconds to purge the lines of 

residual ATF, then close the air purge valve. 

 

14.

 

Remove both spin on filters, install the filter screens on top of the filters, and spin the filters back in 

place on the flusher.  Backflush, if possible, the flusher for 5 minutes.  Cycle off the motor.  Check the 

filter screens.  If no debris is present, toggle off the motor. Then air purge the lines for 15 seconds.  

Now cycle the heater off.  Flushing is complete. Remember to always close the air purge valve. 

 

 

14a. 

If debris is present in the filter screens, repeat the flushing process. 

 

 

 

 

 

 

 

 

 

 

15.  Disconnect the pressure and return hoses from the vehicle cooler lines.   

 

16.  Install the test coupling (provided with your domestic adapter kit) to connect the pressure and return 

 

hoses to each other for storage. 

 

17.  Unplug the flusher from the wall outlet. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ATTENTION 

 

If you feel that you have flushed the vehicle completely and properly, but still see debris in the 

filter screens, check these areas of the flusher:

 

a.

 

Non By Pass (NBP) spin on filters - for damage or pollution 

b.

 

Severe contamination of the holding tank and/or the flusher hoses 

c.

 

Heater - adjust temperature higher 

 

Summary of Contents for Basic TTCF-6

Page 1: ...D Deluxe TTCF 7AR Supreme TTCF HD Heavy Duty Heated Cooler Line Flusher Not all options available on all models TTCF 7AR shown below G TEC Inc 611 Kathryn St PO Box 1079 Nixa MO 65714 800 725 6499 417 725 6400 Fax 417 725 3577 www g tec com ...

Page 2: ...the tank Heater is adjustable however doing so is solely at the risk and responsibility of the operator Adjusting to a higher heat is only recommended on a per need basis After each high temperature job the heater should be turned back to the factory setting of approx 150 160 Never leave the heater adjusted to a high temperature If the temperature ever exceeds 198 degrees the float is designed to ...

Page 3: ...it 3 Install the appropriate quick disconnect line adapters imports or domestic to the ATF cooler inlet and outlet lines using any of the three methods in Picture 1 To forward flushing only Connect the red pressure hose to the cooler inlet line the line going to the external filter Connect the blue return hose to the cooler outlet line the line coming from the vehicle s cooler tank going to the tr...

Page 4: ...t possible set the 7AR reverse lever to the 1 position for a forward flush 9 Cycle on the motor toggle Let the machine flush for 15 minutes Regulate air supply to 90 100 psi 10 While the machine is running open the air purge valve for 10 15 seconds to cause agitation and improve the flushing process Then close the air purge valve for 5 minutes Repeat the opening and closing 3 times 11 Cycle off th...

Page 5: ...open for at least 15 seconds to purge the lines of residual ATF then close the air purge valve 14 Remove both spin on filters install the filter screens on top of the filters and spin the filters back in place on the flusher Backflush if possible the flusher for 5 minutes Cycle off the motor Check the filter screens If no debris is present toggle off the motor Then air purge the lines for 15 secon...

Page 6: ... 4 Frequently monitor the temperature of the fluid using the thermometer during the high heat job making sure the temperature does not exceed 199 5 After completing the high heat job the temperature must be returned to factory settings of 150 160 by turning the rubber tip counter clockwise 6 NEVER leave the heater in the high heat position damage may occur to the machine When the white arrow on to...

Page 7: ...r s drain plug After cleaning refill the tank with 8 9 gallons of clean ATF and as a option you can add one 11 oz bottle of transmission flush Troubleshooting Always unplug the flusher before any troubleshooting Problem No Heat Red Light On Solution 1 Make sure the fluid level is above the float switch or 3 4 from the top of the fill neck 2 If you still have no heat test for 110 V at the heater 3 ...

Page 8: ...turn hoses with the provided coupling so that fluid circulates through the flusher only 4 Increase the heat slightly Problem Shop s Circuit Breaker Tripping Thermal Switch On Motor Tripping Solution 1 Clear entire flushing system of debris Check for restrictions from motor to hoses to connectors etc 2 Make sure the flusher is plugged into a 110 V 20amp outlet with NOTHING else plugged into it 3 Ma...

Page 9: ...ter Bracket Magnetic Spin On Non By Pass Filters Heater Kit Baldor Viking Pump Motor Complete Hose Kit for All Flusher Hoses Manual Handheld Air Purge w Venting Cap Long Handle with Hose Hooks Hose Holding and Tool Tray Holding Bracket Spin On Filter Cross Reference Guide KEEP FOR FUTURE REFERENCE Filter G Tec AC Fram Super Tech Motorcraft STP Non By Pass NBP2 PF34 PF1232 PH3682 ST2827 FL13B FL839...

Page 10: ...event damage To ship by UPS use the 611 Kathryn St address To mail by US Post Office use the P O Box 1079 Include the RGA number on the outside of the package 3 We will repair replace the product and ship it back On items covered under warranty G Tec will determine whether to repair or to replace the defective item s at no charge Item s will be shipped back to customer at G Tec s expense However i...

Page 11: ...ntained herein shall create a warranty for customer s items used in conjunction with Turbo Tank Products or for said equipment Further this warranty shall not extend to any normal wear or usage of the equipment or if the equipment has been improperly installed This warranty is in lieu of any other warranty either expressed or implied Neither G TEC nor Turbo Tank Products is liable for any damage w...

Reviews: