Erasing Accel. Calibration
Use the following procedure to erase the G-tech’s acceler-
ometer calibration data.
Assuming you have performed two calibrations at
two different temperatures, and the G-tech is held
very still, the
Mag
reading should always be very
close to +1.000. The closer the G-tech is to
+1.000, the more accurate your measurements will
be.
If the reading is greater than +1.005 or less than
+0.995 you should erase the current calibration
(p. 144) and then re-calibrate the accelerometers
(p. 28).
The X, Y, and Z fields are provided for engineering
support, and generally you will not need to look at
them.
The current temperature inside the G-tech is also
displayed, as this affects the accelerometers. It is
provided primarily for engineering support.
1
Start in
Configuration Mode
.
2
Select “Calibration” and press
.
Note: DO NOT CALIBRATE ACCELEROMETERS or ERASE ACCELEROMETER CALIBERATION
on G-tech units which were shipped after August 2003. They have already been calibrated in the
factory. Older G-techs will automatically request calibration. If you are unsure contact tech support.
Summary of Contents for Pro Competition
Page 1: ...Update 3 1 1 Dec 2003...
Page 17: ...16 G TECH Pro Competition User Guide Release 3 1...
Page 45: ...44 G TECH Pro Competition User Guide Release 3 1...
Page 93: ...92 G TECH Pro Competition User Guide Release 3 1...
Page 137: ...136 G TECH Pro Competition User Guide Release 3 1...
Page 167: ...166 G TECH Pro Competition User Guide Release 3 1...
Page 174: ......
Page 175: ......
Page 176: ......
Page 178: ......
Page 179: ......
Page 180: ......