第
16
页
8
、
Loosen the adjusting bracket screw of
①
protective cover, adjust the protective cover to the desired
position, and then fasten the adjusting bracket screw of
①
protective cover
。
8.2.2 Installation method of B-bracket
8-3
B-bracket installation
8-4
B-bracket fix surface drilling dimension
Installation steps
:
1
、
Use 4 M6
×
12 hexagon socket head cap screws (ammunition distribution and flat pad) to fix the
①
horizontal mounting bracket to LSD1xxA through the 4 threaded holes on the back of LSD1xxA.
2
、
Use four M8
×
20 hexagon socket head cap screws (ammunition distribution and flat pad) to install the
①
horizontal mounting bracket on the desired fixing surface. See 8-4 for the drilling dimension.
9 Trouble codes and troubleshooting
9.1 Trouble codes
No
Trouble
Description
001
Parameter
configuration fault
Configuration of machine working parameters
through upper computer is incorrect
002
Front lens cover
fault
The cover is polluted or damaged
003
Measurement
reference fault
The measurement data of bright and dark reflectors
inside the machine is incorrect
004
Motor fault
The motor does not reach the set speed, or the speed
is unstable
005
Communication
fault
Ethernet
communication,
measurement
data
transmission blocked or disconnected