Installation, operating and maintenance instructions
Radio locks PRIME OFFICE 2170 (EN 179) for toughened glass doors
10
0-45648-3E-0-GB, modif. 1, sheet 10/20, Mod. No. G24578, www.g-u.com 01/2011
4.3
Mounting the electrical / electronic components
Mounting the wall module:
The wall module is to be mounted in a Ø 55 mm flush box (at the interior) within a max. radius of 4 m from the radio lock PRIME OFFICE 2170
(
see Fig. 10 top
).
Select a place of installation ensuring a direct line of sight between the module and the lock. It is imperative to avoid installation behind
projections on a wall or behind cupboards/shelves, especially of metal, as the radio transmission may be disturbed (
see Fig. 10 bottom
)!
Appropriate plastic dummy covers are available in white or in stainless steel appearance.
ma
x. 4
m
FMIO
FMIO
FMIO
FMIO
max. 4m
Fig. 10:
Installation area of wall module (FMIO)