Installation, operating and maintenance instructions
Radio locks PRIME OFFICE 2170 (EN 179) for toughened glass doors
15
0-45648-3E-0-GB, modif. 1, sheet 15/20, Mod. No. G24578, www.g-u.com 01/2011
7
Error diagnosis
8
Disposal
Radio lock PRIME OFFICE 2170 and wall module FMIO B 5528 0110 must be disposed of as electronic waste
at a spezial waste collection site.
The battery must be expertly disposed of at appropriate collection sites.
The packing must be disposed separately.
Error description
Cause
Correction
Chapter
Two-time activation of motor at battery
insertion
•
Lock is not paired
•
Perform ‚Pairing’
6.1
•
Assign lock to correct wall module
1.2
•
Lock has already been paired with
another wall module
or:
•
Perform ‚Repairing’
and repeat ‚Pairing’
6.2;
6.1
Pairing not possible
•
Pairing time expired
•
Reinsert battery and
repeat ‚Pairing’
5;
6.1
•
Voltage supply failing
•
Check voltage supply of wall module
1.1;
4.3
No visual or acoustical signals
on wall module
•
Defective electronic component
•
Replace wall module,
perform ‚Repairing’,
repeat ‘Pairing’
6.2;
6.1
•
Wrong Pairing adress
•
Perform ‚Repairing’,
repeat ‚Pairing’
6.2;
6.1
•
Battery empty
•
Insert new battery
5
•
Battery inserted in wrong way
•
Verify correct battery polarity
5
No communication with wall module
(no engaging, no status signals)
•
Lock and wall module not within
radio range
•
Reduce distance between lock and
wall module
4.3
•
Battery empty
•
Exchange battery
5
No (electronic) engaging, however
status signals are transmitted to wall
module
•
Poor radio communication
•
Reduce distance between lock and
wall module
4.3
•
Lock seized
•
Slightly loosen fastening screws of
fittings
•
Verify tightening torque of clamping
screws
4.2
4.2
No (mechanical) engaging, however
status signals are transmitted to wall
module
•
Handle not in normal position
•
Handle too heavy
use handle with
hold-up spring
•
Verify fittings / attachment of fittings
4.2
•
Mode ’permanent release’ is active
•
Quit ’Permanent release’
and try again
2.2.2.3
No engaging via cylinder
•
Defective mechanical component
•
Exchange lock
Miscellaneous
•
Call BKS service