49
3.4
Switching points of the multi-point locks
3.4.1 Switching points SECURY 1970 / 1970 EVP / 1971 / 1975
Monitoring contact
for cylinder cam
Description of contacting related to cylinder cam position 0°!
0° = Lever handle not actuated
* Lock case cover = label side of the lock case
0° = Lever handle not actuated
Latchbolt contact
Lever handle contact
lock case cover *
Lever handle contact
lock case bottom
The wiring diagrams for the switching points of the
contacts are shown in the basic position; i.e.:
Latchbolt projected
Lever handle
not
actuated (lever handle position 0°)
Cylinder in the key removal position
(cylinder
cam
not
actuated)
The contacts of the multi-point locks switch within the
areas highlighted in grey.
Rot
Gelb
0°
100°
90°±3°
0°
25°
6°±3°
0°
25°
6°
+10°
−4°
Grau
Grün
Blau
Graurosa
Weißgrün
Schwarz
Rotblau
Violett
Braungrün
Contacting of latchbolt contact (only SECURY 19 EK / SECURY 19 EK EVP for 1-leaf doors **)
through follower
** The 2-leaf door version does not have a latchbolt contact. The latchbolt cannot be queried through the shoot-bolt
lock B-1990X-XX-X-X FSK (
F
allen riegel
s
chalt
k
ontakt - latchbolt contact).
Contacting of monitoring contact for
cylinder cam through profile cylinder
Contacting of lever handle contact
through follower
Red
Yellow
Grey
Blue
Green
Purple
Brown-green
Red-blue
Black
Grey-pink
White-green
Summary of Contents for Secury 19 EK