26
Multi-point locks
General installation instruction
GU-SECURY Automatic Panik |SECURY 19 | SECURY 21
EN
04.2016 | G26788 | Designed in Germany
2.3 Maintenance
Locking systems should be checked at least
once a year
to ensure fi tness
for use. In the process, the proper condition of the locking system must be
ensured.
Perform the following routine maintenance checks and document them
accordingly:
Inspect and actuate the panic exit device and make sure that all parts of
the locking system are in a perfect operating condition.
Make sure that the keepers are not jammed or filled with dirt.
Make sure that no additional locking devices have been fitted to the door
at a later point in time.
Verify that all system components still correspond to the list of approved
components originally supplied with the system. Have the system
serviced to its proper condition at regular intervals.
Make sure the fixing materials are properly tightened and retighten
according to regulation if required.
Lubricate all moving parts, locking points, and the rear of the central and
additional latchbolts with a non-resiniferous grease (e.g., LUMO Special
Grease 8559/1 of Gmelin).
We recommend an additional monthly functional check of the panic exit
device.
Only cleaning and care agents that do not aff ect the corrosion protection of
the hardware parts may fundamentally be used.