If the PILOT is blocked by debris, spider webs etc., the pilot flame might be small and the
flame failure device may have not heated up enough for the main burner to work. If this
happens i tis necessary to clean the pilot and its gas tube.
To clean the PILOT, remove the burner and pilot cover as detailed above, inspect the pilot
injector and tubing for blockage. If obstructed, clean with compressed air. Clean the flame
failure device as well. Assembly is a reversal of above steps.
Technical details:
Appliance category:
3+(28-30/37)
3B/P(30)
3B/P(50)
3B/P(37)
Type of gas:
Butane Propane
Butane,
propane,
their mixture
Butane,
propane, their
mixture
Butane,
propane, their
mixture
Gas pressure:
28 - 30
mbar
37 mbar
29 mbar
50 mbar
37 mbar
Outlet pressure of the
regulator:
30
mbar
37 mba
29 mbar
50 mbar
37 mbar
Injector:
Appliance category:
3+(28-30/37)
3B/P(30)
3B/P(50)
3B/P(37)
Type of gas:
Butane
Propane
Butane,
propane,
their mixture
Butane,
propane, their
mixture
Butane,
propane, their
mixture
Gas pressure:
28 - 30
mbar
37 mbar
29 mbar
50 mbar
37 mbar
Leistungsaufnahme gesamt:
13 kW (butan: 945 g/h, propan: 928 g/h
Injector size:
1,80 mm main burner
0,18 mm pilot burner
1,50 mm main
burner
0,18 mm pilot
burner
1,70 mm main
burner
0,18 mm pilot
burner
The marking (e.g. 1.90 on the injector) indicates that the
size of it is 1.90 mm.
0063/20