Present the card face-on to the reader until you hear a "bleep". The reader is now working correctly. Cards can
be presented in rapid succession; there is no
need, for example, to wait for "GREEN LED’s" to disappear before
presenting another.
When faulted, the reader can not accept a card read. Check wiring for faults or replace reader.
9600-0199.
Installation and User Instructions for S680/690 Readers,
Issue 2.0x1 5th November 2013. G4S Technology, 2013.
FCC Notice:
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation.
Any unauthorized modification to this device may void the authority of
the user to operate it. All trademarks acknowledged.
©
LED Status Indicator
GREEN
–
The lock is released and you may open the door.
RED
–
You do not have access rights to gain entry, or the reader did not read your card properly (in this case,
present it again).
Specifications
Input voltage: 12Vdc.
Input current: 100mA Max.
Operating temperature: -13 to 158°F (-25 to 70°C)
Operating humidity: 90%, non-condensing.
Maximum read range: 4" (100mm).
Approvals: EN300330, EN301489
4
Using / Testing the Reader
3
Reader Connections contd.
TX-
RX+
RX-
680/690 Reader
20mA current loop
Connect shield at
controller end only.
Shielded Belden 9537 7x24 awg cable UL Listed style 2464 (DUZX) cable.
Maximum distance 150m
12V
0V
TX+
RX-
TX+
TX-
12V
0V
RX+
Controller
Note:
Brown wire not used
Red
Black
Green
Orange
White
Blue