background image

Present the card face-on to the reader until you hear a "bleep". The reader is now working correctly.  Cards can
be presented in rapid succession; there is no

 

need, for example, to wait for "GREEN LED’s" to disappear before 

presenting another.

When faulted, the reader can not accept a card read.  Check wiring for faults or replace reader.

 

 

   

 

 

 

 

 

 

 

9600-0199. 

Installation and User Instructions for S680/690 Readers, 

Issue 2.0x1 5th November  2013.   G4S Technology, 2013. 

FCC  Notice: 

This  device  complies  with  Part  15  of  the  FCC  Rules. 

Operation is subject to the following two conditions: (1) This device may 
not  cause  harmful  interference,  and  (2)  this  device  must  accept  any 
interference received, including interference that may cause undesired 
operation.

Any unauthorized modification to this device may void the authority of 
the user to operate it.   All trademarks acknowledged.

©

LED Status Indicator

GREEN 

 

The lock is released and you may open the door.

RED 

 

You do not have access rights to gain entry, or the reader did not read your card properly (in this case, 

present it again).

Specifications

Input voltage:  12Vdc. 
Input current:  100mA Max. 
Operating temperature: -13 to 158°F (-25 to 70°C)
Operating humidity: 90%, non-condensing.
Maximum read range: 4" (100mm).
Approvals: EN300330, EN301489

4

Using / Testing the Reader

3

Reader Connections contd.

TX-

RX+

RX-

680/690 Reader

20mA current loop

Connect shield at 
controller end only.

Shielded Belden 9537 7x24 awg cable UL Listed style 2464 (DUZX) cable.

Maximum distance 150m

12V

0V

TX+

RX-

TX+

TX-

12V

0V

RX+

Controller

Note:

 Brown wire not used

Red

Black

Green

Orange

White

Blue