2
1 IMPORTANT
The following installation instructions are intended to guide
the competent person throughout the entire installation
process.
The boiler’s guarantee does not cover any damage caused by
non-observance of any of these instructions.
These installation instructions and user’s guide must be
conserved and given to any new user.
The symbols used in the text are explained below:
WARNING This indication shows the possibility of
causing death from electric shock.
WARNING This indication shows the possibility
of causing death or serious injury.
CAUTION
This indication shows the possibility
of causing injury or damage to
properties only.
Symbol for useful information.
2 SAFETY
o
This appliance is not destined for use by anyone
(including children) with reduced physical, sensorial
or mental capacities or those who do not know how
to use the appliance, unless they are supervised or
instructed by a person responsible for their safety.
o
Check that the voltage on the indicator plate of the
boiler coincides with the voltage of the mains circuit
to which it is going to be connected.
o
The use of these boilers in the presence of gases,
explosives or inflammable objects is prohibited.
o
The air inputs and outputs of the boiler ensure its
correct operation and protect it from over-heating.
They must never be covered.
o
This boiler must be disconnected from the mains
electricity before carrying out any internal repairs.
o
The boiler must be installed in such a manner that
the switches or other controls cannot be touched by
anyone who is using the bath or shower.
o
The installation must be performed in accordance
with current electricity regulations.
o
This appliance is destined to be permanently
connected to a fixed installation. The power circuit of
the boiler must incorporate an omni-polar cut-off
switch with a separation between the contacts of at
least 3 mm.
o
The electricity supply circuit must incorporate a
Residual-Current Device.
o
This boiler must be earthed.
o
All the models incorporate different safety elements.
If one or more of them are activated, consult the
section 7 TROUBLE SHOOTING.
o
In time, the presence in the air of smoke, dust and
pollution may stain the walls and areas close to the
appliance.
o
Any improper use is forbidden.
o
Do not install the boiler in rooms prone to frost.
3 INTRODUCTION
3.1 DESING & OPERATION
The Gabarrón MATTIRA CMX18i and CMX15i combi boilers
are electrically heated appliances providing wet central heating
through a standard radiator system (or underfloor system
with special kit) and domestic hot water (DHW) delivered
from an integral unvented store at mains water pressure.
Outputs are from 2 to 18kW. Maximum output can be
adjusted to match the heat requirement of the system or the
limitations of the incoming available power supply. Operation
is possible on three phase N or single phase 230V –
(Standard configuration allows a maximum of 12kW in single
phase mode).
The boilers are designed for internal installation on a suitable
wall with consideration for the total weight of the appliance
when full.
A digital control panel provides user control to adjust the
temperatures of heating and hot water. A power modulation
feature automatically adjusts the heating output to the demand
to ensure economic operation. A suitable external time
clock/room thermostat should be fitted (not supplied). All
components for sealed system central heating are built-in.
Heating and hot water functions will operate independently
but not simultaneously, with priority always to hot water
production.
3.2 PRINCIPLE COMPONENTS
•
Insulated steel boiler unit with immersed
stainless steel elements INCOLOY800.
•
50 L stainless steel domestic hot water store
with CFC free insulation and immersed stainless
steel elements INCOLOY800.
•
Fully integrated electronic control boards
featuring temperature control and modulation
function, pump over-run, anti-seize and frost
protection. Self-diagnostic fault information.
•
Sealed system heating components: circulating
pump, expansion vessel, auto air-vent, 3 bar relief
valve, pressure gauge, water flow switch and
temperature limit safety thermostat.
•
Unvented hot water components: 7 bar relief
valve, 2L expansion vessel, non-return valve and
temperature limit safety thermostat
•
Silent TRIAC power switches.
•
Digital control board.