7.- WIRING 

8.- PRODUCT FICHE 

ErP   

MODEL(S): 

GABARRON RBC9, RBC11, RBC14

 

Información 

Symbol 

Value 

Unit 

RBC9 

RBC11 

RBC14 

Heat Output

 

Nominal heat output 

P

nom

1.0 

1.25 

1.5 

kW 

Minimum heat output 

P

min

N.A. 

N.A. 

N.A. 

kW 

Maximum continuous heat output 

P

max,c

1.0 

1.25 

1.5 

kW 

Auxiliary electricity consumption

 

At nominal heat output 

el

max

0.000 

0.000 

0.000 

kW 

At minimum heat output 

el

min

0.000 

0.000 

0.000 

kW 

In standby mode 

el

SB 

<0.0005 

<0.0005 

<0.0005 

kW 

Item 

Value. All 

models 

Type of heat output / room temperature control

Electronic room temperature control plus week timer 

Yes 

Other control options

Room temperature control, with open window detection 

Yes 

With distance control option 

No 

With adaptive start control 

Yes 

Contact details 

ELNUR, S.A.  
Travesía de Villa Esther, 11 
28110 

 Algete (Madrid), Spain 

Commission Regulation (UE) 2015/1188 of 28 April 2015. Ecodesign requirements for electric fixed local space heater. 

Summary of Contents for Elnur RBC11

Page 1: ...sing this appliance for the first time These instructions must be followed for the safe installation of the radiator Any problem fault or damage caused by the non observance of these instructions will...

Page 2: ...n of the appliance They also protect the heater from overheating therefore it is essential that at no time are they covered This heater should be switched off at the isolating switch before any repair...

Page 3: ...on the hooks of the brackets By turning the screws the metallic square will go downwards retaining the heater Repeat this on the other bracket Mark the fixing points on the wall using a pencil through...

Page 4: ...and the day of the week Note When the device enters Stand by mode 2 sounds of duration are output half a second When the device is switched on it emits a sound lasting one second LCD Display Navigatio...

Page 5: ...3 5 C below the Comfort temperature Frost Protection Fixed 7 C are set Eco 1 Maintains the room temperature 1 C below the Comfort temperature Eco 2 Maintains the room temperature 2 C below the Comfort...

Page 6: ...e room In such a case the device deactivates the heating element for a maximum of 30 minutes until at which point the radiator will resume to operate in the previously set state When this function is...

Page 7: ...n the unit is disconnected and cold Do not use solvents or abrasive products for cleaning This thermal radiator has been manufactured under an assured quality system using environment friendly process...

Page 8: ...minimum heat output elmin 0 000 0 000 0 000 kW In standby mode elSB 0 0005 0 0005 0 0005 kW Item Value All models Type of heat output room temperature control Electronic room temperature control plus...

Page 9: ...o the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for t...

Reviews: