background image

Elnur

 

powered by Gabarrón  |  RBC  |   Installation Guide

2

•   The warranty of the heater will not cover any  

   damage caused by non-observance of any of  

these instructions.

•  The instructions should be retained for future    

   reference. This guide must be kept and given to  

any new owner.

•  This appliance can be used by children aged from  

  8 years and above and persons with reduced   

  physical, sensory or mental capabilities or lack of  

  experience and knowledge if they have been given  

  supervision or instruction concerning the use of the  

  appliance in a safe way and understand the hazards  

  involved. Children must not play with the appliance.  

  Cleaning and user maintenance must not be made  

  by children without supervision.
•  Children aged from 3 years and less than 8 years  

  shall only switch on/off the appliance provided  

  that it has been placed or installed in its intended  

  normal operating position and they have been  

  given supervision or instruction concerning use of  

  the appliance in a safe way and understand the  

  hazards involved. Children aged from 3 years and  

  less than 8 years shall not plug in, regulate and  

  clean the appliance or perform user maintenance.
•  Children of less than 3 years should be kept away  

  unless continuously supervised.
•  Please check that the voltage in the rating label fits  

  the power supply.
•  The use of these heaters is forbidden in any area  

  where there is a presence of gases, explosives or  

  inflammable objects.
•  Do not use this heater to dry clothes. Do not cover  

  this heater or put objects in contact with it.
•  Neither the connecting cable nor any other object  

  must come into contact with the hot unit.
•  Do not cover this heater at any time.
•  The air outlet at the top of the thermal radiator and  

  the air inlet at the bottom are provided to ensure the  

  most efficient operation of the appliance. They also  

  protect the heater from overheating; therefore, it is  

  essential that at no time are they covered.

•  This heater should be switched off at the isolating  

  switch before any repair work is carried out.
•  The installation must be carried out in accordance  

  with the current electrical regulations.
•  Should the heater be moved and reinstalled it is  

  essential that the work is carried out by a fully  

  qualified technician.
•  The heater should not be installed just below an  

  electrical socket.
•  The appliance must be installed in such a way that  

  it is impossible for anyone using a bath or shower,  

  to touch the controls.
•  The heater is fitted with a flexible cable size 3 x  

  1.00 mm² for electrical connection. It may be used  

  to connect the heater to the fixed wiring of the  

  premised through a suitable connection box    

  positioned adjacent to the heater.
•  The supply circuit to the heater must incorporate  

  a double pole isolating switch having a contact  

  separation of at least 3 mm.
•  If the flexible power cable for this unit is damaged,  

  it may only be replaced by a repair workshop   

  recognised by the manufacturer, as special tools  

  are necessary.
•  All models are supplied with an electrical interrupt  

  cut-out. This will switch off the heater if, for any  

  reason, it overheats. Should the cut-out operate,  

  turn the heater off and remove the cause for the  

  overheating. The cut-out will be reset automatically.
•  This heater is filled with a precise quantity of special  

  oil. Repairs requiring opening of the oil container  

  are only to be made by the manufacturer or his  

   service agent who should be contacted if there is  

an oil leakage.

•  Regulations concerning the disposal of oil when  

  scrapping the appliance have to be followed.
•  The presence of air particles of smoke, dust and  

  other pollutants could, in time, discolour the walls  

  and surfaces around the heater.

1. WARNING

CAUTION: Some parts of this product can become very hot and cause burns. Particular 

attention must be given when children and vulnerable people are present. 

!

Summary of Contents for Elnur RBC9

Page 1: ...Please read these instructions carefully before installing or using this appliance for the first time Installation Instructions User Guide RBC Thermal Radiators RBC9 RBC11 RBC14 ...

Page 2: ...ce They also protect the heater from overheating therefore it is essential that at no time are they covered This heater should be switched off at the isolating switch before any repair work is carried out The installation must be carried out in accordance with the current electrical regulations Should the heater be moved and reinstalled it is essential that the work is carried out by a fully quali...

Page 3: ... the package and check that it is the correct model and it is in good condition To obtain optimum performances it is necessary to maintain a minimum clearance of 15 cm between the radiator and any inflammable material as furniture curtains etc The rest of clearances required to maintain are indicated on the following figure The studs and screws to attach the supports are in the accessories bag Han...

Page 4: ...ility of 0 1 ºC It is possible to set temperatures with an accuracy of 0 5ºC LCD DISPLAY 3 1 SWITCHING ON THE HEATER Press the On Stand by key to turn on off the unit When the device is active the mode and temperature are displayed During Stand by the display shows the current time and the day of the week Note When the device enters Stand by mode 2 sounds of duration are output half a second When ...

Page 5: ...not occupied for several days 1 Press the Prog key until the display shows the Frost Protection icon ECO FUNCTION This mode lowers the set temperature 3 C regardless of other radiator settings 1 To activate deactivate the function press the dedicated ECO key ECO icon is displayed 11 EN 3 2 COMFORT AND NIGHT TEMPERATURES 2 different levels of temperature can be set Comfort Temperature It is the tem...

Page 6: ...w is potentially opened the Open Window icon starts blinking When the function is disabled the Open Window icon is not shown on the display 3 5 PROGRAMMING Day and time setting 1 Activate Stand by mode and press the clock key for more than 5 seconds to enter configuration menu 2 With the and keys scroll through the menu to the Time function press mode to confirm 3 Day The word day blinks for 2 sec...

Page 7: ...s in the right way 5 TROUBLESHOOTING The thermal radiator does not heat Check the heater or the air inlets are not covered The room does not reach the required temperature Check the selected temperature is in accordance with the desired temperature Maybe the room needs more heating power The display shows an error message Contact the after sales service The keyboard does not respond If the display...

Page 8: ... elmax 0 000 0 000 0 000 kW At minimum heat output elmin 0 000 0 000 0 000 kW In standby mode elSB 0 0005 0 0005 0 0005 kW Item Value All models Type of heat output room temperature control Electronic room temperature control plus week timer Yes Other control options Room temperature control with open window detection Yes With distance control option No With adaptive start control Yes Contact deta...

Page 9: ...l min 0 000 0 000 0 000 kW In standby mode el sb 0 0005 0 0005 0 0005 kW MODEL S GABARRON RBC9 RBC11 RBC14 ErP Item Value All models Type of heat output room temperature control Electronic room temperature control plus week timer Yes Other control options Room temperature control with open window detection Yes With distance control option Yes With adaptive start control Yes Contact details ELNUR U...

Page 10: ...rma adecuada Para obtener información más detallada sobre el reciclaje de este producto póngase en contacto con la administración de su ciudad con su servicio de desechos del hogar o con la tienda donde compró el producto Estas disposiciones solamente son válidas en los países miembros de la UE The symbol on the product or in its packaging indicates that this product may not be treated as househol...