PROGRAM MODE 

In this mode, the ambient temperature is maintained  

at the comfort level or at the Nightly level according  

to time slots programmed as desired by the user.
1.  Press the [mode] key until the corresponding icon  

  appears on the display.
2.  Press [Clock] key to choose P1, P2, P3 programs.

Note:

 To modify pre-set programs P1, P2 or P3,  

see 3.5 Programming.

3.4 ADVANCE FUNCTIONS

Keyboard Lock

 

It is possible to lock the device during any operation 

mode to avoid improper or involuntary use such as 

protecting children or in a public space. 
To turn on / off the keyboard, press the [mode] key  

for 5 seconds. Keyboard lock icon is displayed.

TIMER 2H

The “Timer 2h” mode can be used to quickly warm up 

the room or to speed up.
2.  Press the [Mode] key until the display shows the  

  “2h” icon.
The device is activated at the maximum power for  

2 hours, up to the maximum radiator temperature. The 

“Timer-2h” mode is automatically deactivated after a 

period of 2 hours returning to program mode. The user 

can switch to another operative mode at any time by 

simply pressing the [Mode] key.

ADAPTIVE START CONTROL

This function, if activated, will turn on the radiator in 

advance of the programmed (Max 2 hours) to ensure 

that the room has reached the desired at the set time.
Note: The function takes at least a couple of days to 

reach the maximum efficiency.

OPEN WINDOW DETECTION

The “Open Window Detection” function enables 

detecting of an open window by sensing a sudden 

decrease of the temperature in the room. In such a 

case, the device deactivates the heating element for a 

maximum of 30 minutes until at which point the radiator 

will resume to operate in the previously set state.
When this function is enabled, the “Open Window” icon 

is shown on the display. When the device detects that 

the window is potentially opened, the “Open Window” 

icon starts blinking. When the function is disabled the 

“Open Window” icon is not shown on the display.

3.5 PROGRAMMING

Day and time setting

 

1.  Activate “Stand-by” mode and press the [clock] key  

  for more than 5 seconds to enter configuration menu.
2.  With the [+] and [-] keys, scroll through the menu to  

  the Time function, press [mode] to confirm.
3. 

Day:

 The word “day” blinks for 2 seconds, with the [+]  

  and [-] keys select the Day and confirm with the  

  [mode] key.
4.  

Hour:

 Use the [+] and [-] keys to select the time  

and confirm with the [mode] key.

Minutes:

 Use the [+] and [-] keys to select the minutes 

and confirm with the [mode] key. When finished,  

the device will exit the programming menu.

Program setting

 

Pre-set programming P1, P2 and P3 used in program 

mode can be modified by the user.
1.  Activate the “Program” mode using the [mode] key.  

  Press the [Clock] key to choose which of the  

  programs P1, P2, P3 to set.
2.  Hold the [Clock] key to set the time sequence.
3.  Now a time sequence can be set for each day of the  

  week. It starts with day 1, the time zone is displayed,  

  the desired sequence is selected with [+] and [-]  

  keys.  For each hour, the “Comfort” temperature (2  

  displayed bars) can be set by pressing [+] key and  

  the “Night temperature (1 displayed bar) can be set  

  by pressing [-].
4.  Press [Mode] to confirm the first day setting and  

  enter next day programming.
5.  Repeat the same procedure for the remaining 6 days  

  of the week.

Advance function activation: Open Window 

Detection and Adaptive Start Control

The user can activate or deactivate these functions  

as follows
1.  Activate the stand-by status and press the [clock]  

  key for more than 5 seconds.
2.  With the [+] and [-] keys scroll the menu to the “Func”  

  function and press the [mode] key to confirm.
3.  Open Window Detection icon is displayed. Press  

  the [+] or [-] key to activate or deactivate the open  

  window detection function. Press [Mode] key to  

 confirm.
4.  Adaptive Start Control icon is displayed. Press the  

  [+] or [-] key to activate or deactivate the adaptive  

  start control function. Press [Mode] key to confirm  

  and exit programming.

Summary of Contents for Elnur RBC9

Page 1: ...Please read these instructions carefully before installing or using this appliance for the first time Installation Instructions User Guide RBC Thermal Radiators RBC9 RBC11 RBC14 ...

Page 2: ...ce They also protect the heater from overheating therefore it is essential that at no time are they covered This heater should be switched off at the isolating switch before any repair work is carried out The installation must be carried out in accordance with the current electrical regulations Should the heater be moved and reinstalled it is essential that the work is carried out by a fully quali...

Page 3: ... the package and check that it is the correct model and it is in good condition To obtain optimum performances it is necessary to maintain a minimum clearance of 15 cm between the radiator and any inflammable material as furniture curtains etc The rest of clearances required to maintain are indicated on the following figure The studs and screws to attach the supports are in the accessories bag Han...

Page 4: ...ility of 0 1 ºC It is possible to set temperatures with an accuracy of 0 5ºC LCD DISPLAY 3 1 SWITCHING ON THE HEATER Press the On Stand by key to turn on off the unit When the device is active the mode and temperature are displayed During Stand by the display shows the current time and the day of the week Note When the device enters Stand by mode 2 sounds of duration are output half a second When ...

Page 5: ...not occupied for several days 1 Press the Prog key until the display shows the Frost Protection icon ECO FUNCTION This mode lowers the set temperature 3 C regardless of other radiator settings 1 To activate deactivate the function press the dedicated ECO key ECO icon is displayed 11 EN 3 2 COMFORT AND NIGHT TEMPERATURES 2 different levels of temperature can be set Comfort Temperature It is the tem...

Page 6: ...w is potentially opened the Open Window icon starts blinking When the function is disabled the Open Window icon is not shown on the display 3 5 PROGRAMMING Day and time setting 1 Activate Stand by mode and press the clock key for more than 5 seconds to enter configuration menu 2 With the and keys scroll through the menu to the Time function press mode to confirm 3 Day The word day blinks for 2 sec...

Page 7: ...s in the right way 5 TROUBLESHOOTING The thermal radiator does not heat Check the heater or the air inlets are not covered The room does not reach the required temperature Check the selected temperature is in accordance with the desired temperature Maybe the room needs more heating power The display shows an error message Contact the after sales service The keyboard does not respond If the display...

Page 8: ... elmax 0 000 0 000 0 000 kW At minimum heat output elmin 0 000 0 000 0 000 kW In standby mode elSB 0 0005 0 0005 0 0005 kW Item Value All models Type of heat output room temperature control Electronic room temperature control plus week timer Yes Other control options Room temperature control with open window detection Yes With distance control option No With adaptive start control Yes Contact deta...

Page 9: ...l min 0 000 0 000 0 000 kW In standby mode el sb 0 0005 0 0005 0 0005 kW MODEL S GABARRON RBC9 RBC11 RBC14 ErP Item Value All models Type of heat output room temperature control Electronic room temperature control plus week timer Yes Other control options Room temperature control with open window detection Yes With distance control option Yes With adaptive start control Yes Contact details ELNUR U...

Page 10: ...rma adecuada Para obtener información más detallada sobre el reciclaje de este producto póngase en contacto con la administración de su ciudad con su servicio de desechos del hogar o con la tienda donde compró el producto Estas disposiciones solamente son válidas en los países miembros de la UE The symbol on the product or in its packaging indicates that this product may not be treated as househol...

Reviews: