7.- WIRING 

 
 

 

 
 
 
 

 

 
 
 
 
 

8.- PRODUCT FICHE 

ErP              

MODEL(S): 

GABARRON RBC9, RBC11, RBC14 

 

Información 

Symbol 

Value 

Unit 

RBC9 

RBC11 

RBC14 

Heat Output

 

Nominal heat output 

P

nom 

1.0 

1.25 

1.5 

kW 

Minimum heat output 

P

min 

N.A. 

N.A. 

N.A. 

kW 

Maximum continuous heat output 

P

max,c 

1.0 

1.25 

1.5 

kW 

Auxiliary electricity consumption 
At nominal heat output 

el

max 

0.000 

0.000 

0.000 

kW 

At minimum heat output 

el

min 

0.000 

0.000 

0.000 

kW 

In standby mode 

el

SB 

<0.0005 

<0.0005 

<0.0005 

kW 

 

Item 

Value. All 

models 

Type of heat output / room temperature control

 

Electronic room temperature control plus week timer 

Yes 

Other control options

 

Room temperature control, with open window detection 

Yes 

With distance control option 

No 

With adaptive start control 

Yes 

 

Contact details 

ELNUR, S.A.  
Travesía de Villa Esther, 11 
28110 – Algete (Madrid), Spain 

 

Commission Regulation (UE) 2015/1188 of 28 April 2015. Ecodesign requirements for electric fixed local space heater. 

 

Summary of Contents for Elnur RBC9

Page 1: ...Please read these instructions carefully before installing or using this appliance for the first time Installation Instructions User Guide RBC Thermal Radiators RBC9 RBC11 RBC14 ...

Page 2: ...ce They also protect the heater from overheating therefore it is essential that at no time are they covered This heater should be switched off at the isolating switch before any repair work is carried out The installation must be carried out in accordance with the current electrical regulations Should the heater be moved and reinstalled it is essential that the work is carried out by a fully quali...

Page 3: ... the package and check that it is the correct model and it is in good condition To obtain optimum performances it is necessary to maintain a minimum clearance of 15 cm between the radiator and any inflammable material as furniture curtains etc The rest of clearances required to maintain are indicated on the following figure The studs and screws to attach the supports are in the accessories bag Han...

Page 4: ...ility of 0 1 ºC It is possible to set temperatures with an accuracy of 0 5ºC LCD DISPLAY 3 1 SWITCHING ON THE HEATER Press the On Stand by key to turn on off the unit When the device is active the mode and temperature are displayed During Stand by the display shows the current time and the day of the week Note When the device enters Stand by mode 2 sounds of duration are output half a second When ...

Page 5: ...not occupied for several days 1 Press the Prog key until the display shows the Frost Protection icon ECO FUNCTION This mode lowers the set temperature 3 C regardless of other radiator settings 1 To activate deactivate the function press the dedicated ECO key ECO icon is displayed 11 EN 3 2 COMFORT AND NIGHT TEMPERATURES 2 different levels of temperature can be set Comfort Temperature It is the tem...

Page 6: ...w is potentially opened the Open Window icon starts blinking When the function is disabled the Open Window icon is not shown on the display 3 5 PROGRAMMING Day and time setting 1 Activate Stand by mode and press the clock key for more than 5 seconds to enter configuration menu 2 With the and keys scroll through the menu to the Time function press mode to confirm 3 Day The word day blinks for 2 sec...

Page 7: ...s in the right way 5 TROUBLESHOOTING The thermal radiator does not heat Check the heater or the air inlets are not covered The room does not reach the required temperature Check the selected temperature is in accordance with the desired temperature Maybe the room needs more heating power The display shows an error message Contact the after sales service The keyboard does not respond If the display...

Page 8: ... elmax 0 000 0 000 0 000 kW At minimum heat output elmin 0 000 0 000 0 000 kW In standby mode elSB 0 0005 0 0005 0 0005 kW Item Value All models Type of heat output room temperature control Electronic room temperature control plus week timer Yes Other control options Room temperature control with open window detection Yes With distance control option No With adaptive start control Yes Contact deta...

Page 9: ...l min 0 000 0 000 0 000 kW In standby mode el sb 0 0005 0 0005 0 0005 kW MODEL S GABARRON RBC9 RBC11 RBC14 ErP Item Value All models Type of heat output room temperature control Electronic room temperature control plus week timer Yes Other control options Room temperature control with open window detection Yes With distance control option Yes With adaptive start control Yes Contact details ELNUR U...

Page 10: ...rma adecuada Para obtener información más detallada sobre el reciclaje de este producto póngase en contacto con la administración de su ciudad con su servicio de desechos del hogar o con la tienda donde compró el producto Estas disposiciones solamente son válidas en los países miembros de la UE The symbol on the product or in its packaging indicates that this product may not be treated as househol...

Reviews: