background image

1.- IMPORTANT INFORMATION 

 

  Read these instructions carefully before installing or using this heater for the first time. The 

guarantee will not cover damage caused by not following these instructions. 

  The instructions should be retained for future reference. This guide must be kept and given to 

any new owner. 

  This appliance is designed for domestic use only. 

  The installation must be carried out by trained personnel and in accordance with the current 

electrical regulations. 

  This appliance can be used by children aged from 8 years and above and persons with reduced 

physical, sensory or mental capabilities or lack of experience and knowledge if they have been 
given supervision or instruction concerning the use of the appliance in a safe way and 
understand the hazards involved. Children must not play with the appliance. Cleaning and user 
maintenance must not be made by children without supervision. 

  Children aged from 3 years and less than 8 years shall only switch on/off the appliance 

provided that it has been placed or installed in its intended normal operating position and they 
have been given supervision or instruction concerning use of the appliance in a safe way and 
understand the hazards involved. Children aged from 3 years and less than 8 years shall not 
plug in, regulate and clean the appliance or perform user maintenance. 

  Children of less than 3 years should be kept away unless continuously supervised. 

  Dielectric hoses must be installed both in water inlet and water outlet. The guarantee will not 

cover damage caused if dielectric hoses are not fitted. 

  The use of this water heater is forbidden in areas where gases, explosive or inflammable 

substances are present. 

  Ensure the power supply to the socket into which the appliance is plugged is in accordance with 

the rating label on the heater. 

  This appliance must be earthed. 

  Keep the power cable away from the hot body of the electric water heater. 

  Do not let the cable hang over the edge of a table or counter or let it come into contact with any 

hot surfaces. 

  The improper handling can cause injuries. 

  Do not pull on the connection cord, but rather on the plug, to separate the appliance from the 

mains. 

  Do not use extension cable. This could overheat and cause fires. 

  Never touch the appliance with wet or humid hands or barefoot. 

  The water heater must be disconnected during installation and cleaning. 

  The water heater should not be located in front of, or under an electrical socket.  

  The water heater should be positioned so the controls cannot be used when using the shower 

or bath. 

  The location of the water heater should not be close to curtains or other inflammable articles. 

  It is important to maintain a minimum distance of 80 cm between the water heater and curtains, 

or any other combustible materials. 

  Never dismantle the components of the water heater or replace the components with the ones 

that do not meet the safety requirements. If the supply cord is damaged, it must be replaced by 
the manufacturer or its service agents or a similarly qualified person in order to avoid a hazard. 

  The presences in the atmosphere of tobacco smoke or atmospheric pollution can, with time, 

discolour the heater surface. 

  Do not use outdoor.  

 

 

Summary of Contents for GTS 10

Page 1: ...INSTRUCCIONES DE INSTALACI N Y USO INSTALLATION AND OPERATING INSTRUCTIONS Lea estas instrucciones atentamente antes de instalar o utilizar el aparato por primera vez Please read these instructions b...

Page 2: ...uamente supervisados Es obligatoria la instalaci n de manguitos diel ctricos en la entrada y en la salida de agua La garant a no cubrir los da os causados por la no instalaci n de los mismos El uso de...

Page 3: ...amente La entrada y salida de agua siempre deben quedar en la parte inferior del termo una vez instalado Conexi n hidr ulica Todas las conexiones son G1 2 Antes de proceder a la conexi n hidr ulica es...

Page 4: ...el ctrico de la toma de corriente es adecuado a lo mostrado en la placa de caracter sticas del aparato Conecte el termo a una toma de corriente equipada con una buena toma de tierra Limitador t rmico...

Page 5: ...ngase en contacto con el Servicio de Asistencia T cnica 4 MANTENIMIENTO IMPORTANTE Una vez al mes compruebe que el grupo de seguridad no se encuentra obstruido Col quelo en posici n de drenaje para e...

Page 6: ...x Temperatura agua 75 C 75 C Grado de protecci n IPX4 IPX4 Fijaci n Vertical Vertical Consumo de mantenimiento 0 50 kWh 24h 0 57 kWh 24h Peso vacio 6 3kg 7 8kg Perfil de carga declarado XXS XS Clase...

Page 7: ...guarantee will not cover damage caused if dielectric hoses are not fitted The use of this water heater is forbidden in areas where gases explosive or inflammable substances are present Ensure the pow...

Page 8: ...ce This water heater is to be installed exclusively in vertical position Inlet and outlet must be always in the lower part of the water heater Water connections All the fittings are G1 2 Before making...

Page 9: ...the socket into which the appliance is plugged is in accordance with the rating label on the heater This appliance must be earthed All models are supplied with an electrical interrupt cut out This wi...

Page 10: ...nd get in contact with after sales service 4 MAINTENANCE IMPORTANT Check every month that the Pressure Relief Valve is not blocked Operate the spanner to drainage position If the Pressure Relief valve...

Page 11: ...t 1500W 1500W Voltage 230V 230V Current 6 5A 6 5A Rated Pressure 0 8MPa 0 8MPa Rated Water Temperature 75 C 75 C IP rating IPX4 IPX4 Fixing Vertical Vertical Loss 0 50 kWh 24h 0 57 kWh 24h Net Weight...

Page 12: ...s product equences for the envi propriate waste hand is product please con hop where you purch es www elnur Tf de atenci n a 34 91 628 1 ua Elnur s a se reserva el der t improvement Elnur s a rese 201...