6
4.2 UNPACKING & CONTENTS
- Wall bracket with template.
- Boiler.
- Documentation.
- Bag with parts and fittings.
Dispose of the cardboard packaging at a cardboard recycling site. Observe national regulations.
4.3 LOCATION
WARNING
INSTALL UPRIGHT ON A WALL SUITABLE TO SUPPORT THE TOTAL WEIGHT OF THE
BOILER WHEN FULL OF WATER – 125 kg.
The location should be clean and dry with no presence of gases, explosives
or
flammable objects.
It is not suitable for installation outside and should be protected from
moisture and frost.
The boiler must be sited so that the boiler and controls are not accessible
to any
persons whilst using a bath or shower and there should be no possibility of
water
dripping or splashing onto the boiler or controls.
Electrical safety regulations for clearances must be followed if installed in a
bathroom or shower area.
The boiler has an electric protection rating of IP20/IP2X.
Where possible the boiler should be sited to minimize the pipe distance
to hot
water outlets.
The power supply cable should be carefully routed and secured and
provision
made for a suitable isolation switch and MCB/RCD.
4.4 DIMENSIONS & CONNECTIONS
i
A Safety valve drain DHW.
B Electrical
connection
C Cold water input ½”
D DHW outlet ½”
E Heating flow ¾”
F Heating return ¾”