3
1 IMPORTANT
The following installation instructions are intended to
guide the competent person throughout the entire
installation process.
The boiler’s guarantee does not cover any damage caused
by non-observance of any of these instructions.
Th
ese installation instructions and user’s guide mu
st be
conserved and given to any new user.
Connections can come loose in transit, and all should be
checked before installation.
The symbols used in the text are explained below:
WARNING This indication shows the possibility
of causing death from electric shock.
WARNING This indication shows the
possibility of causing death or
serious injury.
CAUTION
This indication shows the
possibility of causing injury or
damage to properties only.
Symbol for useful information.
2 SAFETY
o
This appliance is not destined for use by anyone
(including children) with reduced physical, sensorial
or mental capacities or those who do not know how
to use the appliance, unless they are supervised or
instructed by a person responsible for their safety.
o
Check that the voltage on the indicator plate of the
boiler coincides with the voltage of the mains circuit
to which it is going to be connected.
o
The use of these boilers in the presence of gases,
explosives or inflammable objects is prohibited.
o
The air inputs and outputs of the boiler ensure its
correct operation and protect it from over-heating.
They must never be covered.
o
This boiler must be disconnected from the mains
electricity before carrying out any internal repairs.
o
The boiler must be installed in such a manner that
the switches or other controls cannot be touched by
anyone who is using the bath or shower.
The installation must be performed in accordance
with current IEE Wiring Regulations, Building
Regulations, Water Fitting Regulations (England &
Wales) or Water Byelaws (Scotland) and all
relevant British Standards
.
o
This appliance is destined to be permanently
connected to a fixed installation. The power circuit of
the boiler must incorporate an omni-polar cut-off
switch with a separation between the contacts of at
least 3 mm.
o
The electricity supply circuit must incorporate a
Residual-Current Device.
o
This boiler must be earthed.
o
All the models incorporate different safety elements.
If one or more of them are activated, consult the
section 7 TROUBLE SHOOTING.
o
In time, the presence in the air of smoke, dust and
pollution may stain the walls and areas close to the
appliance.
o
Any improper use is forbidden.
o
Do not install the boiler in rooms prone to frost.
3 INTRODUCTION
3.1 DESIGN & OPERATION
The Gabarron MATTIRA COMBI boilers are electrically
heated combi boilers providing wet central heating through
a standard radiator system (or underfloor system with
special kit) and domestic hot water (DHW) delivered from
an integral unvented store at mains water pressure.
Outputs are from 2 to 15kW. Maximum output can be
adjusted to match the heat requirement of the system or
the limitations of the incoming available power supply.
Operation is possible on three phase N or single
phase 230V - 50Hz.
The boilers are designed for internal installation on a
suitable wall with consideration for the total weight of the
appliance when full.
A digital control panel provides user control to adjust the
temperatures of heating and hot water. A power
modulation feature automatically adjusts the heating output
to the demand to ensure economic operation.
A suitable external time clock/room thermostat
should be fitted (not supplied).
An adjustable thermostatic blending valve
should be fitted on the hot water supply to
ensure a safe and economic supply of hot water
(not supplied).
i