background image

 

 

EN 

Press the 

+

 key to go to the next interval. The display will show 

00:30

 intermittently and, again, press one of the three keys 

 

 

 to allocate SUN, MOON or OFF (frost protection) from 00:30h to 01:00h or press 

+

 key directly if the existing 

temperature level is ok.

 

Repeat these steps allocating the desired temperatures levels over the 24 hours of the day. Press the 

 

key at any time to 

modify a previous period.  By reaching the 

23:30

 in the display and pressing 

+

 key, the controller will store the program and 

will return to the previous mode. 
At any time 

PRG 

key can be used also to store the program and return the previous mode. 

 

 
 

 

 

1 - Press 

PRG  

 

 

 

 

00:00

 

2 - Press 

   

 

 

 

 

      Off 

 

 

 

3 - Press 

+

 

key

 

 

 

 

 

00:30

 

 

4 - Repeat steps 2 and 3 until display shows: 

 

07:30

 

5 - Press  

 

 

 

 

 

      On 

6 - Press 

+

 

key

 

 

 

 

 

08:00

 

 

7 - Press  

 

 

 

 

 

 

8 - Press 

+

 

key

 

 

 

 

 

08:30

   

9 - Press  

 

 

 

 

 

 

10 - Press 

+

 

key

 

 

 

 

 

09:00

   

11 - Press 

 

 

 

 

 

 

12 - Press 

+

 

key 

 

 

 

 

09:30

   

13 - Repeat steps 11 and 12 until display shows: 

 

13:00

 

14 - Press  

 

 

 

 

 

 

15 - Press 

+

 

key

 

 

 

 

 

13:30

   

16 - Repeat steps 14 and 15 until display shows: 

 

15:00

 

17 - Press 

 

 

 

 

 

 

18 - Press 

+

 

key

 

 

 

 

 

15:30

 

 

19 - Repeat steps 17 and 18 until display shows: 

 

19:30

 

20 - Press  

 

 

 

 

 

 

21 - Press 

+

 

key

 

 

 

 

 

20:00

   

22 - Repeat steps 20 and 21 until display shows:

    

23:30

 

23 - Press  

 

 

 

 

 

 

24 - Press 

+

 

key

 

 

 

 

 

GRAB

 

 
 

00:00

 

01:00

 

02:00

 

03:00

 

04:00

 

05:00

 

06:00

 

07:00

 

08:00

 

09:00

 

10:00

 

11:00

 

12:00

 

13:00

 

14:00

 

15:00

 

16:00

 

17:00

 

18:00

 

19:00

 

20:00

 

21:00

 

22:00

 

23:00

 

24:00

 

 

SUN

 

MOON

 

OFF

 

EXAMPLE

 

 

Let’s  see

  an  example  of  how  to  introduce  a 

program  with  the  above  distribution  of 
temperatures. 
 
OFF  from  24:00h  to  7:30h  in  the  morning. 
The heater will be on only if the temperature 
drops to 3ºC. 
 
SUN temperature from 7:30h to 9:00h. 
 
MOON temperature from 9:00h to 13:00h. 
 
SUN temperature from 13:00h to 15:00h. 
 
MOON temperature from 15:00h to 19:30h. 
 
SUN temperature from 19:30h to 24:00h. 

Summary of Contents for PH-125 Plus

Page 1: ...before installing or using this appliance for the first time These instructions must be followed for the safe installation of the radiator Any problem fault or damage caused by the non observance of...

Page 2: ...ure the most efficient operation of the appliance They also protect the heater from overheating therefore it is essential that at no time are they covered This heater should be switched off at the iso...

Page 3: ...d any inflammable material as furniture curtains etc The studs and screws to attach the supports are in the accessories bag Fix the two square brackets to the back of the heater by using the two small...

Page 4: ...n key If the display shows the time the heater is in frost protection mode Press this key to shift from frost protection mode to standard mode and vice versa Heating indicator This small dot will be l...

Page 5: ...ey to set the SUN temperature The display will show the SUN temperature value blinking Set the SUN temperature value by means of the o keys and press the key to store the value If the display shows th...

Page 6: ...ss 8 Press key 08 30 9 Press 10 Press key 09 00 11 Press 12 Press key 09 30 13 Repeat steps 11 and 12 until display shows 13 00 14 Press 15 Press key 13 30 16 Repeat steps 14 and 15 until display show...

Page 7: ...play shows dia7 the weekly program will be stored by pressing key If the display shows dia1 then pressing key more than three seconds will copy the day 1 program to day 2 and so on It is possible to a...

Page 8: ...urning off the main switch at the right side of the heater the display will be Off Press the key and at the same time turn on the main switch maintaining the key at least five seconds The display will...

Page 9: ...r Err2 Contact the after sales service Only daily programmes The controller is in single 24hr mode factory default See WEEKLY PROGRAMMES section to switch to 24hr 7days mode The keyboard does not resp...

Page 10: ...9 EN 10 WIRING...

Page 11: ...ary electricity consumption In standby mode elSB 0 68 0 68 0 68 0 68 W Item Value All models Type of heat output room temperature control Electronic room temperature control plus week timer Yes Other...

Page 12: ...is product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is...

Reviews: