background image

 

ON

              

  

3. - USING THE THERMAL RADIATOR 

 

 
MODELS RKSHi 
 

ON

 

 

LCD DISPLAY:  LCD 

display shows the information related to the heater operation. 

 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 
 

 
ADJUSTMENT OF THE SET POINT TEMPERATURE 

 
COMFORT set point temperature may be adjusted from 7ºC to 30ºC in 0.5ºC steps.  

Pressing the keys 

“+”

 

or

  

“–” 

the set point temperature is increased/reduced respectively. After three seconds if no other key is pushed the 

selected value is stored in memory. 
 
The set point temperature in ECONOMIC mode is the COMFORT setting temperature reduced by 3.5ºC. 
 
The setting temperature in FROST-PROTECTION mode is 7ºC and it is constant.  
 
 

CORRECTION OF TEMPERATURE MEASURES 
 

If there is a difference between temperature values on an external thermometer and the temperature 
displayed by the unit, it is possible to change the sensor settings in order to balance the difference (-5ºC to 
+5ºC, in 0.5ºC steps). 
 

In order to make changes hold the 

“mod.” 

key for more than five seconds and after that with buttons 

“+”

 

or  

“–” 

increase or decrease the correction to 0.5ºC respectively.   Press the 

“mod.”

 key to store the 

correction in memory and proceed with the next setting.  

Key  

“+”

Press the key to 
increase the 
COMFORT set point  
temperature.  

Key  

“-”

Press the key to 
decrease COMFORT 
set point temperature.  

ON/OFF key:  

Push the button to switch 
on/off the heater. Also you 
may lock/unlock the 
keyboard by maintaining it for 
several seconds. 

OPERATION MODE KEY: 

Press the key to select 
operation mode: 

permanent COMFORT,  

permanent 
ECONOMICAL, 

permanent FROST 
PROTECTION 

 AUTOMATIC modes.  

 

Example of the heater permanent COMFORT mode,  

Set point temperature is 20.5ºC, showing ON output 

condition. 

 

The heater is OFF. 

 

Main switch.  
All models are 
equipped with one 
switch on the back 
surface allowing 
the heater 
disconnection.   

Summary of Contents for RKS10Hi

Page 1: ...ER GUIDE INTERTIA ELECTRIC RADIATOR RKS4Hi RKS6Hi RKS8Hi RKS10Hi RKS12Hi RKS14Hi RKS4L RKS6L RKS8L RKS10L RKS12L RKS14L Please read these instructions before installing or using this appliance for the first time IECEE IECEE CB SCHEME ...

Page 2: ...so be taken during the times of the year when heat is not required The thermal radiator should not be installed just below an electrical socket or in front of a socket outlet The appliance must be installed in such a way that switches and other control devices cannot be touched by a person using a bath or shower The installation must be carried out in accordance with the current electrical regulat...

Page 3: ... change the sensor settings in order to balance the difference 5ºC to 5ºC in 0 5ºC steps In order to make changes hold the mod key for more than five seconds and after that with buttons or increase or decrease the correction to 0 5ºC respectively Press the mod key to store the correction in memory and proceed with the next setting Key Press the key to increase the COMFORT set point temperature Key...

Page 4: ... and FROST PROTECTION are prior and independent from the operation mode selected in the heater OPERATION WITH A PROGRAMMER WITH POWER LINE CARRIER OR A LOAD CONTROLER WITH POWER LINE CARRIER In AUTOMATIC mode it is possible to control the heater operation from a programmer with PLC Power Line Carrier or from a load controler with PLC TO ASSOCIATE the heater switch the PLC programmer or the PLC loa...

Page 5: ... the operation to set minutes Press the ON OFF key to exit These four keys perform different operations depending on the message of the LCD display Press two central buttons at a time for several seconds to lock unlock the keyboard ON OFF key Press the key to switch from OFF to OPERATION Operation mode key Press the key to select different operation modes or to set the system time Main switch All ...

Page 6: ...NT FROST PROTECTION MODE AUTOMATIC REMOTE PROGRAMMER MODE 1 2 3 4 5 6 7 PROG AUTO c 0h 2 4 6 8 10 12 14 16 18 20 22 24 c AUTO c c When the unit is in OFF symbol is displayed together with premises temperature value To switch on the unit to ON mode press the key Last operation mode before the unit had been switched off will be displayed Press the same key to switch off the unit and pass to OFF Appl...

Page 7: ...ntarily the premises temperature PERMANENT FROST PROTECTION MODE In permanent frost protection mode the unit will operate when the premises temperature decreases lower than 7ºC In this mode pressing the i key displays momentarily the premises temperature AUTOMATIC INTERNAL PROGRAMMER MODE In this mode the unit performs commands of the internal programmer Programming By default the program Comfort ...

Page 8: ... control To unlock the keyboard press simultaneously central keys and for several seconds OK SAND GLASS KEY Press the key to adjust the specified temperature for certain determined time By keys or adjust the set point temperature and store by pressing the OK Adjust the time required by keys or and press OK to store ABSENCE KEY Press the key to switch on the Frost Protection mode from 1 day to 365 ...

Page 9: ...nd press OK to store and pass to the next setting ECO set point temperature value may be stored independently from the CONFORT temperature value To authorize ECO value modification press and hold the key until it displays the message and store pressing OK In such a way when selecting the permanent economical mode it will be possible to assign any temperature with or key displayed at selection of p...

Page 10: ...ds Clean dust with a dry soft cloth only when the unit is disconnected and cold Do not use solvents or abrasive products for cleaning After the heating season disconnect the radiator with the switch located on the back surface of the radiator This thermal radiator has been manufactured under an assured quality system using environment friendly processes Please take the heaters to a clean point onc...

Page 11: ...2 5 cm separation from the wall HEIGHT cm 58 WEIGHT 8 kg 11 kg 14 kg 17 kg 20 kg 23 kg 8 kg 11 kg 14 kg 17 kg 20 kg 23 kg POWER 500W 750W 1000W 1250W 1600W 2000W 500W 750W 1000W 1250W 1600W 2000W ISOLATION CLASS II VOLTAGE 220 240V Connect the black wire marked Fil Pilote to the signal wire when available Do not connect this wire to any EARTH lead Connect L and N wires to a fix wall socket or to a...

Page 12: ...ver the heater The symbol on the product or in its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which co...