PERMANENT COMFORT MODE  

 
In permanent comfort mode the unit maintains constantly the set point temperature.  
It is possible to modify COMFORT set point temperature in 0,5ºC steps by pressing the  

keys  

“+”

 

or

  

“–”

Temperature range is from 5 to 30ºC. 
 
When the heater consumes power, ON message is displayed.  

Pressing the

 “i”

 will momentarily display the premises temperature. 

 
 

PERMANENT ECONOMICAL MODE 
 

In economical mode the unit maintains all the time the ECONOMICAL set point temperature.  
 
 
Originally the economical set point temperature is the comfort set point temperature reduced by 3.5ºC. 
 
See menu 1 of CONFIGURATION paragraph to modify the reduction or even to select economic set 
point temperature.  

Pressing the 

“i”

key displays momentarily the premises temperature. 

 
 
 
 

 
PERMANENT FROST PROTECTION MODE  

 
In permanent frost protection mode the unit will operate when the premises temperature decreases lower 
than 7ºC. 
 
In this mode pressing the “i” key displays momentarily the premises temperature. 
 
 

 
 
 
 
AUTOMATIC INTERNAL PROGRAMMER MODE 
 

In this mode the unit performs commands of the internal programmer. 

 

Programming 

 
By default the program “Comfort fro 8h to 22h is applied for all days of the week.  
 
 
 
 
 
 
To modify the program press the “PROG” key in this mode or in OFF mode.  
 
Select the temperature level for the first time interval of the day 1 by pressing one of the following keys:  

Pressing 

 displays two segments indicating COMFORT temperature. 

Pressing 

 display one segment indicating ECONOMICAL temperature.  

 

Pressing 

 does not display any segment, indicating FROST PROTECTION temperature.  

 
After programming all 24 intervals for the DAY 1, press “OK” to pass to the DAY 2 of the week and repeat 
the procedure.   
 
 
Fast Programming 
To copy the complete program from one day to another hold the “OK” key for 3 seconds.  

 
 
 
 
 

Summary of Contents for RKS10Hi

Page 1: ...ER GUIDE INTERTIA ELECTRIC RADIATOR RKS4Hi RKS6Hi RKS8Hi RKS10Hi RKS12Hi RKS14Hi RKS4L RKS6L RKS8L RKS10L RKS12L RKS14L Please read these instructions before installing or using this appliance for the first time IECEE IECEE CB SCHEME ...

Page 2: ...so be taken during the times of the year when heat is not required The thermal radiator should not be installed just below an electrical socket or in front of a socket outlet The appliance must be installed in such a way that switches and other control devices cannot be touched by a person using a bath or shower The installation must be carried out in accordance with the current electrical regulat...

Page 3: ... change the sensor settings in order to balance the difference 5ºC to 5ºC in 0 5ºC steps In order to make changes hold the mod key for more than five seconds and after that with buttons or increase or decrease the correction to 0 5ºC respectively Press the mod key to store the correction in memory and proceed with the next setting Key Press the key to increase the COMFORT set point temperature Key...

Page 4: ... and FROST PROTECTION are prior and independent from the operation mode selected in the heater OPERATION WITH A PROGRAMMER WITH POWER LINE CARRIER OR A LOAD CONTROLER WITH POWER LINE CARRIER In AUTOMATIC mode it is possible to control the heater operation from a programmer with PLC Power Line Carrier or from a load controler with PLC TO ASSOCIATE the heater switch the PLC programmer or the PLC loa...

Page 5: ... the operation to set minutes Press the ON OFF key to exit These four keys perform different operations depending on the message of the LCD display Press two central buttons at a time for several seconds to lock unlock the keyboard ON OFF key Press the key to switch from OFF to OPERATION Operation mode key Press the key to select different operation modes or to set the system time Main switch All ...

Page 6: ...NT FROST PROTECTION MODE AUTOMATIC REMOTE PROGRAMMER MODE 1 2 3 4 5 6 7 PROG AUTO c 0h 2 4 6 8 10 12 14 16 18 20 22 24 c AUTO c c When the unit is in OFF symbol is displayed together with premises temperature value To switch on the unit to ON mode press the key Last operation mode before the unit had been switched off will be displayed Press the same key to switch off the unit and pass to OFF Appl...

Page 7: ...ntarily the premises temperature PERMANENT FROST PROTECTION MODE In permanent frost protection mode the unit will operate when the premises temperature decreases lower than 7ºC In this mode pressing the i key displays momentarily the premises temperature AUTOMATIC INTERNAL PROGRAMMER MODE In this mode the unit performs commands of the internal programmer Programming By default the program Comfort ...

Page 8: ... control To unlock the keyboard press simultaneously central keys and for several seconds OK SAND GLASS KEY Press the key to adjust the specified temperature for certain determined time By keys or adjust the set point temperature and store by pressing the OK Adjust the time required by keys or and press OK to store ABSENCE KEY Press the key to switch on the Frost Protection mode from 1 day to 365 ...

Page 9: ...nd press OK to store and pass to the next setting ECO set point temperature value may be stored independently from the CONFORT temperature value To authorize ECO value modification press and hold the key until it displays the message and store pressing OK In such a way when selecting the permanent economical mode it will be possible to assign any temperature with or key displayed at selection of p...

Page 10: ...ds Clean dust with a dry soft cloth only when the unit is disconnected and cold Do not use solvents or abrasive products for cleaning After the heating season disconnect the radiator with the switch located on the back surface of the radiator This thermal radiator has been manufactured under an assured quality system using environment friendly processes Please take the heaters to a clean point onc...

Page 11: ...2 5 cm separation from the wall HEIGHT cm 58 WEIGHT 8 kg 11 kg 14 kg 17 kg 20 kg 23 kg 8 kg 11 kg 14 kg 17 kg 20 kg 23 kg POWER 500W 750W 1000W 1250W 1600W 2000W 500W 750W 1000W 1250W 1600W 2000W ISOLATION CLASS II VOLTAGE 220 240V Connect the black wire marked Fil Pilote to the signal wire when available Do not connect this wire to any EARTH lead Connect L and N wires to a fix wall socket or to a...

Page 12: ...ver the heater The symbol on the product or in its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which co...

Reviews: