9
PROG
c
>10 sec.
OK
1
2
3
4
5
6
7
c
número
de menú
OK
1
2
3
4
5
6
7
OK
1
2
3
4
5
6
7
c
c
CONFIGURATION
It is possible to configure various parameters of the unit.
In OFF mode press for 10 seconds
“
ON/OFF
”
key to enter the first configuration
menu. It is necessary to pass through five menus to exit the configuration. The
Menu number is displayed above in the right part of the display.
Menu 1: Adjusting the ECO set point temperature.
By default the Economic set point temperature value is equal to
comfort temperature value reduced by 3,5ºC.
The reduction value may be modified from 0 a 10ºC in 0,5°C steps.
For this purpose modify the value with the keys
“+”
/
“–”
and press
“
OK
”
to store
and pass to the next setting.
ECO set point temperature value may be stored independently from the CONFORT
temperature value.
To authorize ECO value modification press and hold the
“+”
key until it displays the
message "
----
and store pressing
“
OK
”
.
In such a way when selecting the permanent economical mode it
will be possible to assign any temperature with
“+”
or
“–”
key displayed at selection of
permanent economical mode.
Selection range will start from 4.5ºC to the comfort set point temperature.
Menu 2: Correction of temperature measures.
If there is a difference between an external thermometer indication and the temperature
displayed by the unit, in menu 2 it is possible to influence on the sensor in order to balance
the difference. (-5ºC to +5ºC,) in 0,1ºC steps.
To modify press the keys
“+”
or
“–”
, after press the
“
OK
”
key and proceed with the
next setting.