5
3/14
MAINTENANCE
WARNING
:
EXCESSIVE CONTACT WITH HYDRAULIC FLUID AND LUBRICANTS SHOULD BE AVOIDED.
WARNING:
MAINTENANCE PERSONNEL
MUST
READ AND UNDERSTAND ALL WARNINGS AND CAUTIONS.
WARNING
:
DISCONNECT TOOL FROM ITS POWER SOURCE BEFORE PERFORMING MAINTENANCE.
WARNING
:
BE SURE POWERUNIT IS DISCONNECTED BEFORE CLEANING OR WHEN REPLACING WORN
OR DAMAGED COMPONENTS. SEVERE PERSONAL INJURY MAY OCCUR IF POWER SOURCE
IS NOT DISCONNECTED.
The performance of any tool depends upon good maintenance practices. Following these minimal
requirements for service and care will extend the life of your tool.
*Only use a hydraulic power source equipped with relief valves and pressures set within
specified limits.
*Keep hydraulic system free of dirt. Avoid letting couplers contact a dirty floor.
*Do not use as a hammer to force fasteners into holes or otherwise abuse tool.
*Proper care by operators is necessary in maintaining full productivity and reducing downtime.
*Keep nose assemblies, especially jaws, clean and free of chips and debris. Lube jaws and collet surfaces
that jaws ride on with light machine oil on a daily basis.
*All Screwed End Caps, Base Covers, Air Fittings, Triggers, Screws and Nose Assemblies are to be
examined at the end of each working shift to check that they are secure.
*Check tool, all hoses and all couplings daily for damage or hydraulic leaks. Tighten or replace
(if necessary
).
HYDRAULIC THREAD PREPARATION
IMPORTANT:
Be sure to use thread sealant on all hydraulic fittings, Loctite® 30534 or similar Teflon® infused pipe
dope is recommended.
CAUTION:
Teflon tape is an excellent thread sealer, however, if it is not
properly applied, pieces of Teflon may enter the hydraulic system and cause malfunction or damage.
Use 1 1/2 wraps of tape on each thread. Cut off all loose tape ends. Tighten until fitting feels snug and
then go 1/2 to a full turn past that point.
CAUTION:
Over tightening can easily distort the threads.
DESCRIPTION
WARNING
:
The balance of this tool is designed for horizontal use and is not ergonomically best suited
for all applications. Gage Bilt will be pleased to advise for your specific application.
The
GB705NAST
hydraulic installation tools designed specifically for the efficient installation of a wide
range of blind rivets and lockbolt fasteners thru 3/16" diameter. They weigh just over 3 lbs.
(1.36kg)
and can
be operated in any position with one hand. They have a .500”
(12.7mm)
rivet setting stroke and a rated pull
load of 5825 lbs.
(25.9 kN).
The
GB705NAST
installation tool operates on hydraulic pressure developed by the GB940 Powerunit set at
5700 psi.
(393.0 bar)
maximum PULL pressure and 2400 psi
(165.5 bar)
maximum RETURN pressure. The
tool comes equipped with a 12’ hydraulic hose with quick disconnects and a electric control cord assembly .
NOSE ASSEMBLIES ARE NOT FURNISHED WITH THE TOOL AND MUST BE ORDERED SEPARATELY.
Note: Gage Bilt does not recommend using a pneumatic lubricator or adding pneumatic oil to the air inlet
on our tools or powerunits.