14
REV. 3/21
GB714 INSTALLATION TOOL
.
S/N: 1001 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.
REMOVING 704130 ACTUATOR ASSY
-
AIR
1.
Remove pin
-
slotted (400608) and actuator lever assy (704343) from handle assy (744129).
2.
Insert a
5/8”
open end wrench around actuator assy
-
air (704130).
3.
Loosen the actuator assy
-
air (704130).
4.
Remove wrench. Unthread and remove the actuator assy
-
air (704130) with fingers from the
handle assy (744129).
INSTALLING 704130 ACTUATOR ASSY
-
AIR
1.
Apply Teflon® tape onto threads of actuator assy
-
air (704130) one to two wraps.
2.
Thread the actuator assy
-
air (704130) all the way into handle assy (744129) with fingers.
3.
Insert and turn
5/8”
wrench and snug tight approximately 1/4
-
1/2 turn.
4.
Reattach pin
-
slotted (400608) and actuator lever assy (704343) to handle assy (744129).
ACTUATOR ASSY
-
AIR
WARNING
:
Disconnect tool from its power source before actuator removal or installation. Severe personal injury may occur if
power source is not disconnected.
CAUTION:
Actuator assy
-
air (704130) can break if not careful.
CAUTION:
Do not over tighten actuator assy
-
air (704130). Snug tighten only.
OVERHAUL