12
Rev 1/23
GB751SH INSTALLATION TOOL S/N: 1364 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.
1.
Stand handle assembly (744129) on floor, stretch hose and head cylinder assembly (703119) upward and lay flat on a table or bench.
When bleeding tool always keep the head cylinder assembly (703119) higher than the handle assembly (744129).
2.
Remove button head cap screw (402482) and stat
-
o
-
seal (S572) from manifold
-
handle (744303) hole marked #3. Attach air bleeder
assembly (704153) to manifold
-
handle (744303) hole marked #3 in an upright position.
3.
Connect the tool to air supply and cycle tool ten times holding the lever (704345) down for 2
-
3 seconds between cycles to remove
any air from the tool.
4.
Disconnect air supply. Remove air bleeder assembly (704153) from manifold
-
handle (744303) and replace with button head cap
screw (402482) and stat
-
o
-
seal (S572) on hole marked #3 and torque to 35
-
40 inch lbs. (3.95
-
4.52 Nm). Do not over tighten.
5.
Remove button head cap screw (402482) and stat
-
o
-
seal (S572) from bleeder hole on head cylinder assembly (703119) and attach
air bleeder assembly (704153) in an upright position.
6.
Connect air supply. Cycle tool ten times removing any air bubbles.
7.
Disconnect air supply. Remove air bleeder assembly (704153) and replace button head cap screw (402482) and stat
-
o
-
seal (S572)
and torque to 35
-
40 inch lbs. (3.95
-
4.52 Nm). Do not over tighten.
8.
Connect air supply. Cycle tool ten times and check stroke of
.780” (19.81
mm) using instructions a thru c and diagrams below.
We recommend using dial calipers.
a. With the lever (704345) released, check dimension (A).
b. Holding lever (704345) check dimension (B).
c. Subtract dimension (A) from dimension (B). If stroke is not consistent within 1/64" (.396 mm) repeat bleeding steps 5
-
8.
For your consideration, Gage Bilt offers a depth gage (Pt.# A
-
1935) to help simplify and more accurately check your tool stroke.
Please contact Gage Bilt for more information.
BLEEDING PROCEDURE:
Hole marked #3 on
Manifold Handle (744303)
Images may not reflect actual tool.
Note:
•
Air Bleeder Assembly (704153) (sold separately) is required.
* FILLING & BLEEDING VIDEO AVAILABLE AT:
http://www.gagebilt.com/rivet_tools_videos.php
WARNING:
Do not cycle tool without air bleeder assembly (704153), or the screw and stat
-
o
-
seal, installed in tool head. Severe
personal injury could result.
WARNING:
Use CAUTION when removing screws, air bleeder assembly (704153) and fill bottle (745263). Hydraulic oil may be
under pressure.
CAUTION:
Before filling handle assembly (744129), air piston assembly (744121) must be all the way down.
CAUTION:
When forcing piston rod assembly (744136) downward, with head cylinder (703119) removed, hydraulic oil will eject forcibly
from handle assembly (744129).
CAUTION:
When bleeding tool, ensure tubing is free from kinks or other obstructions.
Air Bleeder
Assembly
(704153)