14
Rev. 2/17
GB784
REMOVING 704130 ACTUATOR ASSY-AIR
1. Insert a 5/8” (15.9 mm) open end box wrench around actuator assy-air (704130).
2. Loosen the actuator assy-air (704130).
3 Remove wrench. Unthread and remove the actuator assy-air (704130) with fingers from the
handle assy (744129).
INSTALLING 704130 ACTUATOR ASSY-AIR
1. Apply Teflon® tape onto threads of actuator assy-air (704130) one to two wraps.
2. Thread the actuator assy-air (704130) all the way into handle assy (744129) with fingers.
3. Insert and turn 5/8” (15.9 mm) open end box wrench and snug tight approximately 1/4-1/2 turn.
ACTUATOR-AIR
WARNING
:
Disconnect tool from its power source before actuator removal or installation. Severe personal injury may
occur if power source is not disconnected.
CAUTION:
Actuator assy-air can break if not careful.
CAUTION:
Do not over tighten actuator assy-air. Snug tighten only.
OVERHAUL