8

 

8/18 REV. 2/23

 

 

GB808HVB

-

100 INSTALLATION TOOL

 

 

HOW TO SET

-

UP THE GB808HVB

-

100 POWER UNIT

 

WARNING: 

Only qualified and trained operators shall install, adjust or use the assembly power tool for non

-

threaded 

 

 

 mechanical fasteners. 

 

 

WARNING: 

Operator 

MUST 

read and understand all warnings and cautions.

 

 

WARNING: 

It is required that eye protection, hearing protection and foot protection be worn during operation. 

 

 

WARNING: 

The users or the user

s employer must assess specific risks that could be present as a result after each use 

 

 

      based on their application.

 

 

 

 

 ●  

Ensure there is adequate clearance for tool and operator's hands before proceeding. Keep fingers clear of any 

 

 

 

 

moving parts. Keep fingers clear from fasteners and installed materials. Severe personal injury may result.

 

 

 

 

 ●  

Verify that hydraulic hose fittings and couplings, air and electrical connections are secure.

 

 

 

                          

●  

Verify 

the air lines and/or hydraulic hoses are not a trip hazard.

 

 

 

 

 ●  

Ensure that there are no electrical cables, gas pipes, etc., which can cause a hazard if damaged by the tool.

 

 

 

                   

●  

Ensure Do not use as a hammer to force fasteners into holes or otherwise abuse tool.

 

 

WARNING: 

Do not actuate fastener in the air. Personal injury from fastener ejecting may occur.

 

 

 

WARNING: 

Do not use in explosive atmosphere.

 

 

WARNING: 

Ensure air hose is securely connected to avoid possible hose whipping.

 

 

WARNING: 

Always disconnect air supply when tool is not in use to prevent accidental start

-

up.

 

 

CAUTION:

 

Do not use beyond the design intent.

 

Images may not reflect actual tool

 

 

The powerunit is shipped with a plastic plug in the air inlet connector. The connector has a 1/4 

-

 18 NPT female pipe thread to accept 

end

-

user air hose fitting. The tool comes with oil and is ready to use.

 

 

  

1.  Remove red plastic plug in the air inlet connector and install male air fitting with 1/4 

-

 18 NPT. (Not sold with powerunit).

 

 

 

2.  Connect powerunit to power unit by attaching hydraulic hose, air line and vacuum line. 

 

 

 

3.  Connect air supply to powerunit using 

1/2” 

air line min. (90 

-

 100 P.S.I.) (6.2 

-

 6.9 bar) required.

 

 

   

         Note: Gage Bilt does NOT recommend using a pneumatic lubricator or adding oil to the air inlet on our tools or powerunit.

 

 

4.

 

 Connect connection wire to inductive sensor. Plug power cord into 110V outlet. (Power supply in electrical enclosure and inductive 

 

 

 

   

sensor have lights that turn green when power supplied).

 

 

 

5.  Cycle the powerunit (with tool attached) several times. Re

-

check the hydraulic oil reservoir level with the powerunit in the RETURN position.

Check for leaks.

See installation tool manual for complete set up installation instructions.

 

Tool rests on hook when 

not in use, shutting off air 

flow to vacuum

 

Pintails extracted from tool and 

collected in collection bottle

 

Connect pintail evacuation 

tube to tool

 

PNP Output

 

Air Filter/Regulator

 

Incoming Plant Air

 

90 PSI (6.2 bar) Min.

 

Pintail Collection bottle

 

110V  Power Cord

 

Power Supply

 

Inductive Sensor

 

Connection Wire

 

Electrical Enclosure

 

Summary of Contents for GB808HVB-100

Page 1: ...TOOLS ARE AVAILABLE WORLDWIDE E MAIL US FOR A DISTRIBUTOR NEAR YOU ORIGINAL INSTRUCTIONS 44766 Centre Court Clinton Twp MI 48038 USA Ph 1 586 226 1500 Fax 1 586 226 1505 solutions1 gagebilt com www ga...

Page 2: ...n of Functions 5 Safety Warnings 6 Principle of Operation 7 How to set up the GB808 Series Power Unit 8 9 How to use the GB808 Series Power Unit 10 Maintenance Troubleshooting and Hydraulic Thread Pre...

Page 3: ...anty shall be limited to the repair or rework of the goods supplied or replacement thereof at Seller s option and in no case is to exceed the invoice value of said goods Under no circumstances will th...

Page 4: ...ener installation tools When the GB808 is properly configured with the correct installation tool it is capable of installing 3 32 2 38mm 1 4 6 35mm fasteners It is designed specifically to improve on...

Page 5: ...Vacuum Inlet Hydraulic Outlet Air Inlet Pintail Evacuation Air Outlet Spent Pintail Collection Hanging Lever for Tool Regulator Oil Reservoir Cap Inductive Sensor Connection Wire Hooks for hanging pow...

Page 6: ...l weight it is recommended safety shoes be worn during operation 11 It is recommended tool be operated not more than 50 out of every 60 minutes where prolonged use is expected REPETITIVE MOTIONS HAZAR...

Page 7: ...aulic oil up and into the front side of the head cylinder assembly causing the head piston to move to the rear of the head cylinder assembly The internal components of the attached nose assembly are a...

Page 8: ...nect air supply when tool is not in use to prevent accidental start up CAUTION Do not use beyond the design intent Images may not reflect actual tool The powerunit is shipped with a plastic plug in th...

Page 9: ...tall adjust or use the assembly power tool for non threaded mechanical fasteners WARNING Operator MUST read and understand all warnings and cautions WARNING It is required that eye protection hearing...

Page 10: ...ers clear of any moving parts Keep fingers clear from fasteners and installed materials Severe personal injury may result Verify that hydraulic hose fittings and couplings air and electrical connectio...

Page 11: ...AW 32 or equivalent to maintain correct oil level Available in quart size Gage Bilt A 768 WEEKLY MAINTENANCE 703515 Vacuum Regulator Tube 4 S H C S Fitting Image may not reflect actual tool HOW TO CLE...

Page 12: ...educe air pressure to 50 psi 3 45 bar during bleeding procedure 6 Point the bleed port towards a container push actuator lever down and hold Block bleed port using a small piece of rubber material bef...

Page 13: ...forming overhaul Severe personal injury may occur if power source is not disconnected WARNING Excessivecontactwithhydraulicoilandlubricantsmustbeavoided Seesafetydatasheetdocumentsforallapplicablemate...

Page 14: ...14 8 18 REV 2 23 GB808HVB 100 INSTALLATION TOOL OVERHAUL BOOSTER ASSEMBLY...

Page 15: ...15 8 18 REV 2 23 GB808HVB 100 INSTALLATION TOOL GB808HVB 100 POWERUNIT BOOSTER ASSEMBLY GB808HVB 100 POWERUNIT QUICK EXHAUST VALVE...

Page 16: ...16 8 18 REV 2 23 GB808HVB 100 INSTALLATION TOOL GB808HVB 100 POWERUNIT VALVE ASSEMBLY GB808HVB 100 POWERUNIT REGULATOR ASSEMBLY...

Page 17: ...17 8 18 REV 2 23 GB808HVB 100 INSTALLATION TOOL GB808HVB 100 POWERUNIT GB808HVB 100 POWERUNIT...

Page 18: ...18 8 18 REV 2 23 GB808HVB 100 INSTALLATION TOOL GB808HVB 100 POWERUNIT VACUUM BOTTLE ASSEMBLY GB808HVB 100 POWERUNIT FRAME ASSEMBLY...

Page 19: ...19 8 18 REV 2 23 GB808HVB 100 INSTALLATION TOOL GB808HVB 100 POWERUNIT SENSOR ELECTRICAL ENCLOSURE...

Page 20: ...20 8 18 REV 2 23 GB808HVB 100 INSTALLATION TOOL GB808HVB 100 POWERUNIT WIRE DIAGRAM...

Page 21: ...OPERTIES Flashpoint 300 EXTINGUISHING MEDIA Water spray dry chemical CO2 Foam PROTECTION OF FIRE FIGHTERS Special Firefighting Procedures Water or foam may cause frothing Use water to keep fire expose...

Page 22: ...ve Styles Sold Separately Compatible with Gage Bilt and Huck Air hydraulic installation tools GB808 POWERUNIT Sold Separately GB808 WHEELS OPTIONAL Image may not reflect actual tool Hose kites availab...

Page 23: ...23 8 18 REV 2 23 GB808HVB 100 INSTALLATION TOOL This page intentionally left blank...

Page 24: ...ISTERED TRADEMARK OF CHEVRON INTELLECTUAL PROPERTY LLC SLIC TITE IS A REGISTERED TRADEMARK LA CO INDUSTRIES Images may not reflect actual tools Alternative Styles Sold Separately Compatible with Gage...

Reviews: