30
Flat ducts
The inner cross-section must correspond to the
diameter of the round pipes.
150 mm diameter, approx. 177 cm
2
120 mm diameter, approx. 113 cm
2
▯
Flat ducts should not have any sharp deflections.
▯
Use sealing strips for different pipe diameters.
Electrical connection
m
Risk of electric shock!
Components inside the appliance may have sharp
edges. These may damage the connecting cable. Do not
kink or pinch the connecting cable during installation.
The required connection data can be found on the
rating plate inside the appliance; to do this, remove the
metal mesh grease filter.
Length of the cable: approx. 1.30 m
This appliance complies with the EC interference
suppression regulations.
m
Risk of electric shock!
It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket which has
been correctly installed. If the plug is no longer
accessible following installation of the appliance, or a
fixed connection is required, an all-pole isolating switch
must be present on the installation side with a contact
gap of at least 3 mm. The fixed connection must only be
installed by an electrician.
Preparing the units
▯
The fitted unit must be level and have sufficient
load-bearing capacity.
▯
The max. weight of the extractor hood is 18 kg.
Appliance dimensions and safety clearances
▯
Observe the appliance's dimensions.
▯
Comply with the safety clearances.
If the installation instructions for the gas cooking
appliances specify a different distance, the largest
distance must always be provided for.
The fitted unit must be heat-resistant up to 90 °C.The
fitted unit must still be sturdy after the cut-outs have
been made.
To install the extractor hood in a wall-hanging cupboard,
the extractor hood must be provided with the following
dimensions:
1
Make the cut-out for the exhaust air pipe. To do this,
make an opening in the top or back panel of the
fitted unit with an additional recess for the power
cord.
2
If the cabinet base is in place, remove it. Mark the
fastening points on the inside of the cabinet and
use a bradawl to make indentations where the holes
are to be. To help you mark the fastening points,
use the mounting piece provided.
Width
600 mm
Depth
Min. 320 mm
Depth
Min. 350 mm with lowering frame
Height
Min. 420 mm
Height
Min. 600 mm with CleanAir air recircula-
tion module
PP
PP
PLQ
PP
Summary of Contents for AF210
Page 114: ...Gaggenau ...
Page 115: ...Gaggenau ...