background image

9

3.2 Special functions

Intensive level

You should select the intensive level when
browning and frying in an open pan. 

Switching on: 

(Fig. 10)

– Turn the control knob to a ventilation level (1-3).
– Press the intensive level key. The intensive level

symbol appears on the display. The previously
selected ventilation level flashes on the display.
After a few minutes, the appliance switches
back automatically to the previously selected
ventilation level.

or
– Press the intensive level key. The intensive level

symbol appears on the display. The appliance 
is now operated at the intensive level for a few
minutes and then switches off automatically.

Ending the intensive level prematurely:

– Turn the “Ventilation level” knob to the 0 position

or 

– turn the “Ventilation level” knob to any level or 
– press the intensive level key once again.

After-running

Switching on:

– Press the 

(After-running) key.

– The 

(After-running) symbol and ventilation

level 2 light up on the display (Fig. 11).

or
– Turn the “Ventilation level” control knob to any

level.

– Press the 

(After-running) key.

– The 

(After-running) symbol and the set

ventilation level light up on the display (Fig. 12).

– The extractor hood continues running for 

10 minutes. 

Switching off:

– Turn the “Ventilation level” control knob to the 0

position.

or
– Press the 

(After-running) key.

0

0

1

2

3

Fig. 10

Fig. 11

Fig. 12

0

0

1

2

3

Summary of Contents for AH600790

Page 1: ...Operating and assembly instructions AH 600 790 Extractor hood 0 0 1 2 3 ...

Page 2: ... and operating principle Page 6 7 2 1 Structure of the appliance Page 6 2 2 Accessories special accessories Page 6 2 3 Operating principle Page 7 3 Operation Page 8 9 3 1 Switching on and off Page 8 3 2 Special functions Page 9 4 Cleaning and care Page 10 11 5 Maintenance Page 12 6 Assembly instructions Page13 19 6 1 Technical data Page 13 6 2 Installation Page 14 19 ...

Page 3: ... the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting value of your appliance You will find notes on Page 5 that you ought to observe before operating the appliance for the first time The chapters entitled Structure and operating principle and Operation will tell you all the things your extractor h...

Page 4: ...b Always turn hood ON when cooking at high heat or when cooking flaming foods c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a cl...

Page 5: ...ioning Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short circuits Isolate the appliance from the mains during every maintenance operation To do this actuate the corresponding fuse Repairs must be carried out by authorised specialists thus ensuring electrical safety No warranty claims can be lodged in the event of damage caused by f...

Page 6: ...ing the appliance for the first time Remove the packaging from the appliance and dispose of it properly Pay attention to the fact that there are accessories in the packaging Keep packaging elements out of the reach of children Thoroughly clean the appliance before using it for the first time see chapter entitled Cleaning and care Before operating the appliance for the first time check that the mai...

Page 7: ...lation level display 7 Coanda level key 8 Light control knob 9 Ventilation level control knob 10 After running key 11 After running symbol 12 Grease filter saturation symbol 13 Coanda level symbol 14 Intensive level symbol 15 Intensive level key Installation accessories Exhaust air Ventilation duct for ceiling heights of 2 35 2 66 m 7 7 8 6 LK 600 010 Ventilation duct for ceiling heights of 2 66 3...

Page 8: ...arcoal filter special accessory must be installed The fan in the extractor hood sucks in kitchen vapours and returns them to the kitchen after purification in the grease and activated charcoal filter The grease filter absorbs the greasy components in the kitchen vapours The activated charcoal filter binds odour particles see Fig 5 The Coanda effect Kitchen vapours are extracted even better with th...

Page 9: ...t any time To do this turn the Light control knob to the Light position Switching on the Coanda level Turn the Ventilation level control knob to the level you require Press the Coanda level key The level you have set and the Coanda level symbol appear on the display Fig 9 Note You can change to any ventilation level and the Coanda level remains set Switching off the Coanda level Press the Coanda l...

Page 10: ... the intensive level for a few minutes and then switches off automatically Ending the intensive level prematurely Turn the Ventilation level knob to the 0 position or turn the Ventilation level knob to any level or press the intensive level key once again After running Switching on Press the After running key The After running symbol and ventilation level 2 light up on the display Fig 11 or Turn t...

Page 11: ...ximum temperature of 65 C 150 F Place the grease filters vertically in the dishwasher to ensure that no food remainders will stay on them Slight discoloration can occur when cleaning the grease filters in a dishwasher When replacing the grease filters wipe out the inner part of the housing with hot detergent solution Reinsert the grease filters in the hood after cleaning Install them in the revers...

Page 12: ...the two tabs in the downward direction and remove the activated charcoal filter from the hood in the downward direction see Fig 14 Replace the old activated charcoal filter by the new one Install in the reverse order Cleaning the extractor hood Clean the stainless steel parts of the extractor hood with mild rinsing detergent and apply stainless steel care agent to the metal surfaces using a soft c...

Page 13: ...nauthorised tampering with the appliance will invalidate any warranty claims Only ever use original spare parts Lamp replacement Caution Disconnect the power supply before replacing lamps Caution Lamps may still be hot shortly after use Risk of burns Remove the grease filters Remove the screws on the lamp cover The lamp cover tilts down and cannot be removed from the appliance Fig 15 Turn the lamp...

Page 14: ...ing instructions He must explain to the user how the appliance can be isolated from the mains whenever required Connection possibilities The extractor hood was conceived for the exhaust air or air recirculation mode The exhaust air can be routed into a separate exhaust air shaft or directly into the open through the outside wall It must be possible to isolate all poles of the appliance from the ma...

Page 15: ...st be observed when installing the hood The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appliances 600 mm 24 and for gas appliances 670 mm 261 2 The wall hood was conceived for the exhaust air or air recirculation mode The exhaust air can be routed into a separate exhaust air shaft or directly into the open through the outside wall It is not allowed to p...

Page 16: ...owing accessories to install the air recirculation hood KF 600 090 activated charcoal filter Depending on the ceiling height the following duct units are at your disposal for air recirculation LK 600 110 Ventilation duct for a ceiling height of 2 43 2 66 m 7 10 8 6 LK 600 120 Ventilation duct for a ceiling height of 2 66 3 00 m 8 6 9 9 The dimensions above refer to a distance of 1 60 m 5 5 16 from...

Page 17: ... two hooks e with the countersunk screws d Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the included dowels a in the other drill holes Note Pay attention to any special accessories that you may have to fit Screw on the retaining bracket for the chimney paneling Detach the grease filters Unscrew the two black plates on the ...

Page 18: ...top of the chimney into the base Make sure that the fastening holes on the side are at the top Secure the top duct unit with 2 screws on the ceiling holder Pull the shoe down into its final position Fig 22 Note Avoid scratches when fitting the elements into one another by placing the assembly template for example over the edge of the bottom chimney paneling to protect it Reinsert the grease filter...

Page 19: ...s e with the countersunk screws d Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the included dowels a in the other drill holes Note Pay attention to any special accessories that you may have to fit Detach the grease filters Unscrew the two black plates on the left and right of the chimney Hang the hood on the two hooks Adju...

Page 20: ...he 6 screws 3 5 x 9 5 mm Fig 26 Fit the top of the chimney into the base Make sure that the fastening holes on the side are at the top Secure the top duct unit with 2 screws on the ceiling holder Pull the shoe down into its final position Fig 27 Note Avoid scratches when fitting the elements into one another by placing the assembly template for example over the edge of the bottom chimney paneling ...

Reviews: