Exhaust Air

11

3

/

16

"

Exhaust-air mode

Installation accessories for exhaust air
mode.

Ventilation duct

AD280-016 for ceiling heights of 
89

3

/

8

”–96

1

/

16

AD280-026 for ceiling heights of 
96

1

/

16

”–108

21

/

32

AD280-036 for ceiling heights of 
108

21

/

32

”–117

21

/

64

”.

Prior to installation

The exhaust air is discharged upwards through a
ventilation shaft or directly through the outside wall
into the open.

Exhaust air should neither be directed into a smoke
or exhaust flue that is currently used for other
purposes, nor into a shaft that is used for
ventilating rooms in which stoves or fireplaces are
also located.

Exhaust air may be discharged in accordance
with official and statutory regulations only (e.g.
national building regulations).

Local authority regulations must be observed when
discharging air into smoke or exhaust flues that are
not otherwise in use.

When the extractor hood is operated in exhaust-
air mode simultaneously with a different burner
which also makes use of the same chimney 
(such
as gas, oil or coal-fired heaters, continuous-flow
heaters, hot-water boilers) care must be taken to
ensure that there is an adequate supply of fresh
air 
which will be needed by the burner for
combustion.

Safe operation is possible provided that the
underpressure in the room where the burner is
installed does not exceed 4 Pa (0.04 mbar).

This can be achieved if combustion air can flow
through non-lockable openings, e.g. in doors,
windows and via the air-intake/exhaust-air wall box
or by other technical measures, such as reciprocal
interlocking, etc.

If the air intake is inadequate, there is a risk of
poisoning from combustion gases which are
drawn back into the room.

An air-intake/exhaust-air wall box by itself is no
guarantee that the limiting value will not be
exceeded.

Note: When assessing the overall requirement, the
combined ventilation system for the entire
household must be taken into consideration. This
rule does not apply to the use of cooking
appliances, such as hobs and ovens.

Unrestricted operation is possible if the extractor
hood is used in recirculating mode – with activated
carbon filter.

If the exhaust air is going to be discharged into
the open, 
a telescopic wall box should be fitted into
the outside wall.

Ø 6"

Ø 6"

Summary of Contents for AI 280720

Page 1: ...Extractor hood AI 280720 Gaggenau Operating and installation instruction...

Page 2: ...settings b Always turn hood on when cooking at high heat or when cooking flaming foods c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan...

Page 3: ...ng procedure 8 Intensive setting 9 Special functions 9 Filters and maintenance 10 Grease filters 10 Saturation indicator F 10 Activated carbon filter 11 Cleaning and care 12 Replacing the light bulbsn...

Page 4: ...easures such as reciprocal interlocking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by...

Page 5: ...racted particularly well at the front of the cooking field The Coanda effect may allow you to operate the extractor hood at a lower quieter level than you were previously accustomed to The Coanda air...

Page 6: ...ging elements out of the reach of children Thoroughly clean the appliance before using it for the first time Before operating the appliance for the first time check that the mains connection is in pro...

Page 7: ...user Do not place any heavy objects on the appliance Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short circuits Isolate the appliance...

Page 8: ...ight Fan follow on Intensive setting The most effective method of removing vapours produced during cooking is to Switch the ventilator ON as soon as you begin cooking Switch the ventilator OFF a few m...

Page 9: ...l running time to 3 5 or 10 minutes by simultaneously pressing the Int key and the 1 2 or 3 key and you can store this setting When delivered the appliance is set to five minutes i e the combination o...

Page 10: ...has not started to flash Cleaning the metal grease filters In normal operation 1 to 2 hours daily the metal grease filter must be cleaned 1 x a month The filters can be cleaned in a dishwasher It is h...

Page 11: ...moving and inserting the metal mesh grease filters 2 Insert the activated carbon filter 3 Insert the metal grease filters see Removing and inserting the metal grease filters Replacing the activated ca...

Page 12: ...sk of fire and ensures that the extractor hood continues operating at maximum efficiency Clean the operating buttons with a mild soapy solution and a soft damp cloth only Do not use stainless steel cl...

Page 13: ...a risk of being burnt 2 Remove the metal mesh filters see Removing and inserting the metal mesh grease filters 3 Loosen the screws for the mounting rails 4 Carefully remove the glass panes 5 Remove t...

Page 14: ...9 Tighten the screws for the mounting rails 10 Insert the metal grease filters see Removing and inserting the metal grease filters 11 Restore the power by inserting the mains plug or switching on the...

Page 15: ...haust air shaft or directly into the open through the outside wall It is not allowed to pass the exhaust air into a flue or exhaust air chimney that is in operation or into a shaft that is linked to t...

Page 16: ...The extractor hood must not be installed over a solid fuel cooker a potential fire hazard e g flying sparks unless the cooker features a closed non removable cover and all national regulations are obs...

Page 17: ...such as gas oil or coal fired heaters continuous flow heaters hot water boilers care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combus...

Page 18: ...ch can be attributed to the design and layout of the pipework Round pipes We recommend Internal diameter 6 Flat ducts must have an internal cross section that equates to that of round pipes There shou...

Page 19: ...od should only be connected to an earthed socket that has been installed according to relevant regulations If possible site the earthed socket directly behind the chimney panelling The earthed socket...

Page 20: ...es 5 16 for the wall plugs Push the plugs flush with the ceiling 3 Turn two screws to a 25 64 gap Both screws are placed in a position in which at a later stage of the installation the key holes of th...

Page 21: ...nd attach it with all 4 screws to the ceiling Circulating air mode only assemble the circulating air switch module and fix it to support frame Cut the flexible air pipe to the required length and fix...

Page 22: ...chimney duct unit which has no magnetic strips with 2 screws on the top of the support frame 14 The second top chimney duct which has magnetic strips should be slightly bent open in order to slide ov...

Page 23: ...23 KF001 010...

Page 24: ...nau 5551 McFadden Avenue Huntington Beach CA 92649 Telephone 877 4GAGGENAU USA www gaggenau usa com Gaggenau Hausger te GmbH Carl Wery Stra e 34 81739 M nchen Germany www gaggenau com 9000384450 EB 88...

Reviews: