Preparing the ceiling
•
The ceiling must be flat and horizontal.
•
Make sure that the ceiling can bear the applied
loads.
•
The provided screws and wall plugs are
suitable for solid masonry. On all other wall
types (e.g. plasterboard, porous concrete,
Poroton bricks) use the appropriate fasteners.
•
Ensure that the ceiling is capable of providing a
firm hold for mounting screws and plugs.
Weight in kg:
We reserve the right to construction changes within
the context of technical development.
Electrical connection
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: Fitting a Different Plug:
The wires in the mains lead are coloured in
accordance with the following code:
Green
– Earth
White
– Neutral
Black
– Live
If you fit your own plug, the colours of these wires
may not correspond with the identifying marks on
the plug terminals.
This is what you have to do:
1
Connect the green (Earth) wire to the terminal
in the plug marked ‘E’ or with the symbol (
<
),
or coloured green or green and yellow.
2
Connect the white (Neutral) wire to the terminal
in the plug marked ‘N’ or coloured black.
3
Connect the black (Live) wire to the terminal
marked ‘L’, or coloured red.
The extractor hood should only be connected to
an earthed socket that has been installed
according to relevant regulations.
If possible, site the earthed socket directly behind
the chimney panelling.
•
The earthed socket should be connected via its
own circuit.
•
If the earthed socket is no longer accessible
following installation of the extractor hood,
ensure that there is a permanently installed
disconnector.
If it is necessary to wire the extractor hood
directly into the mains:
The extractor hood should only be connected to the
electricity supply by a properly qualified electrician.
A separator must be installed in the household
circuit. A suitable separator is a switch that has a
contact gap of more than
1
/
8
” and interrupts all
poles. Such devices include circuit breakers and
contactors.
몇
If the connecting cable for this appliance is
damaged, the cable must be replaced by the
manufacturer or his customer service or a similarly
qualified person in order to prevent serious injury to
the user.
Electrical data
Are to be found on the name plate inside the
appliance after removal of the filter frame.
몇
Before undertaking any repairs, always
disconnect the extractor hood from the electricity
supply.
Length of the connecting cable: 52”.
This extractor hood corresponds to EC regulations
concerning RF interference suppression.
Exhaust-air
Recirculating air
42,5
44,5