To use this appliance in France, it is necessary to
remove the L-tube mounted in the factory and assemble
the one supplied in the accessory bag. Fig. 6. Do not
forget to insert the seal. If, for some reason, the L-tube
should be twisted, it is necessary to make sure that this
area is properly sealed. Make sure that all connections
performed are free of leakage.
The manufacturer does not accept any liability for leakage
on connections performed by the installer or if the L-tube is
moved or twisted.
4
-Check the voltage and total power on the
characteristics plate. The appliance must be EARTHED.
Make sure that connection has been performed in
accordance with legal regulations in force for the country
in question and complies fully with the conditions laid
down by the local electricity company.
In order to meet normal safety standards, the installer must
supply an all-pole circuit breaker with a contact aperture of
at least 3 mm. This is not necessary when connection is
made via a socket, so long as this is accessible to the user.
Appliances equipped with plugs should only be connected
to sockets which are duly earthed.
The appliance is type "Y". This means that the input supply
cable cannot be changed by the user. Only the brand's
service technicians are qualified to replace this cable. Use
the right cable type and section.
Do not tamper inside the appliance. If necessary, call our
Service Centre.
Hobs with control knobs are supplied with a plugged or
unplugged power cable.
TYPES OF CABLE
5
-In order to complete the installation process, you must
place the diffusers and the tops of the burners on their
corresponding burners. Also you must place the grids
correctly on their supporting elements. Fig. 7.
Changing the type of gas
Before connecting the appliance to the supply, check that
it is prepared for the type of gas in question. Our hobs
leave the factory set for the gas type indicated on the
characteristics plate.
Depending on the regulations in force in your country, this
hob may be adapted to work with other types of gas (see
characteristics plate). To adapt the gas type, proceed as
follows:
1
-Remove the grates, covers and burner core.
2
-Change the injectors using a 7-mm socket wrench and
be sure to tighten them down properly so that they are fully
air-tight. Fig. 8.
It is not necessary to adjust the primary air on these
burners.
B )
Adjusting reduced consumption on the burner valves.
1
- Set the valves to minimum.
2
- Remove the control knobs from the valve shafts. Fig. 9.
3
- It has a flexible rubber seal. Simply apply pressure with
the tip of the screwdriver to release the thread toward the
tap´s adjusting screw. Fig. 10.
Do not remove the disc seal.
4
-Adjusting the by pass screw.
For Propane and Butane Gas: the screw must be
tightened down fully.
For Natural Gas: turn the screw in an anticlockwise
direction until the correct release of gas is reached: when
the burner is changed from the maximum to minimum
settings, the flame does not go out or backfire.
protect against any liquids that may spill from the hob.
6
- Re-assemble the control knobs. Never dismount the
C) Put the label which indicates the type of gas the
appliance has been adapted to near the characteristics
plate.
Rigid connection.
its factory-set position.
All gas 3 x 0.5 mm2
Power cable:
Hob:
en
an authorised installation engineer, respecting
of the gas and electricity providers.
conversion to other types of gas must be carried out by
All operations relating to installation, regulation and
You are recommended to contact the Technical
applicable regulations, standards and the specifications
Assistance Service to convert to another type of gas.
and gas supply.
Before you begin, turn off the appliance' s electricity
A )
Changing the injectors on the burners (see table II).
3
-The end of the input collector on gas hobs comes with a
Hotplates connection
In either of the cases, do not move or twist the L-tube from
and passing the tube through spaces liable to get blocked.
tube and moving parts on the housing (e.g. drawers)
If this method is used, avoid both contact between this
Connection to a flexible metal tube (L min. 1m. - max. 3m.)
1/2” (20.955 mm) threaded L-tube, Fig. 3a. This caters for:
5
- It is important that all the reinforcement rings are in
the entire valve.
place in order to ensure that the electrics are sealed to
valve shaft (fig. 11): in the event of damage, change
Summary of Contents for CG270110F
Page 3: ...5 FR FR FR 6 7 4a 4b 11 11 _0 _0 ...
Page 4: ...9 10 7 mm 8 11 ...
Page 31: ......
Page 32: ...Cod 9000169472 G ...