10
6.1 Technical data
Appliance dimensions:
610 mm x 520 mm
Features:
SuperQuick cooking zone
Ø 140 mm (1200 W)
SuperQuick cooking zone
Ø 180 mm (1800 W)
SuperQuick cooking zone
Ø 170 mm (1500 W)
with connection to
the roasting zone
Ø 170 mm x 265 mm (2400 W)
SuperQuick cooking zone
Ø 140 mm (1000 W)
with connection to
Ø 210 mm (2200 W)
6.2 Important notes on installation
The appliance must only be connected by an
authorised specialist
, paying attention to the
relevant regulations of the power supply companies
and the regional construction regulations.
The installing technician
is responsible for the
correct functioning of the appliance at the time of
installation. He must instruct the user on how to
operate the appliance correctly on the basis of
the Operating Instructions, and the user must be
instructed on how to disconnect the appliance
in an emergency.
When unpacking the appliance, make sure you do
not damage its seal.
No warranty claims can be lodged for any damage
resulting from failure to observe these instructions.
This cooker corresponds to
heat class Y
and must
be installed in a cabinet as detailed in the sketch
(Fig. 9).
This appliance may be installed in kitchen
combinations made of wood or similar combustible
materials, without taking additional measures. Pay
attention to the 'Important notes' (Chapter 1).
Pay attention
to the information on the rating
plate and connect the PE conductor. Connect the
connecting lead to the mains. The
distance
from
the lower edge of the housing trough to the next
combustible item of furnishing at the side should
be
at least 20 mm.
If the range is not installed over a built-in cooker,
protection against hazardous contact
from
below must be ensured after assembly, e.g. by
installing an intermediate shelf that can only be
detached using a tool.
The distance between the intermediate shelf and
the worktop in which the range is recessed must be
at least
60 mm.
If it is not possible to disconnect the appliance
from the mains via an easily accessible plug and
permanent cable connection, an isolating switch
with a contact clearance of
at least 3 mm
must be
fitted on the installation side.
Technical modifications reserved.
Connection to the power mains:
Power rating: 7.6 kW
When connecting electrical appliances and
devices in the proximity of cooking surfaces and
ovens, make sure that connecting cables do not
come into contact with hot cooking surfaces.
If the appliance is installed in a base cabinet that is
less than 60 cm wide, the housing may be in contact
with the cabinet side panels. The cabinet side
panels must be modified so that the appliance is
not in contact with them.
Note:
do not stick the cooking surface onto the
worktop with silicone!
CK 236-114
FD xxxx
230 V AC 50/60 Hz
max. 7600 W
CK 236-214
FD xxxx
400 V AC 50 Hz
max. 7600 W
6. Assembly instructions