1.
Check filter parts: filter cartridge, filter head with wall
mount and hose with two gaskets.
2.
Shut off power.
3.
Shut off water supply externally.
4. Attention:
Pay attention to the direction of the water flow
when mounting the hoses:
Please see filter head
„IN“ = water inlet „OUT“ = water
outlet
5.
Mount inlet hose with gaskets to your cold water supply
and the other side to the IN inlet at the filter head. Mount
the outlet hose to the OUT outlet of the filter head and to
your steamer.
6.
Remove the protective cap (1). Make sure not to touch the
cartridge head. Insert the filter cartridge (4) vertically into
the filter head (2). The filter cartridge can only be inserted
when the locking handle is open.
7.
Turn the locking handle (3) until you feel it engage. Place a
bucket under the grey hose and push the button (5) at the
filter head to remove air from the cartridge (flush 2l).
8.
The P1000 filter cartridge can be operated vertically or
horizontally.
9.
Optional: Attach the wall mount in place using two match
-
ing screws and two wall plugs if necessary, depending on
the type of wall. Engage the filter head in the wall mount.
Please use the fixation holes.
10. Turn on water supply and switch on power.
11. Check complete system for any leaks.
If any leaks are
found, repeat necessary steps.
12.
When everything is in order, the steam oven is ready for
use with the MAVEA filter. If any problems occur, contact
your Gaggenau service team.
Attention:
1.
Protect the P1000 water filter cartridge from direct
sunlight and mechanical damage. Do not assemble near
sources of heat and open flames. A stop valve must be
installed before the filter system intake hose. If the water
pressure is greater than 125 psi, a pressure reducer must
be installed in front of the filter system. Do not use aggres
-
sive cleaning fluid.
2.
The P1000 filter cartridge is only suitable for domestic
use.
3.
Only water of drinking water quality may be used as intake
water for the MAVEA water filter system. The MAVEA water
filter system is only suitable for cold water use within the
supply water temperature stated in the technical data. No
microbiologically impaired water or water of unknown
quality may be used.
4.
If there are official instructions to boil tap water, the filter
system must be decommissioned. When the requirement
to boil water comes to an end, the filter cartridge must be
replaced and the connections cleaned.
5.
The filter system must not be opened or dismantled during
operation. The filter cartridge must not be opened. The
filter system is designed for a service life of 5 years
counted from the date of installation. After five years the
filter head needs to be exchanged.
An independent institute certifies the food grade quality of
MAVEA water filter products.
Exclusion of liability
MAVEA shall not be held liable for any damage, including
subsequent damage, arising from the incorrect use of the
product.
Technical data
Operating pressure
25 psi to max.
125 psi,
or
2 kg/cm
2
to max.
8.8 kg/cm
2
Water intake temperature
39°F to 86°F /
4°C to 30°C
Ambient
temperature for
operation
39°F to 104°F /
4°C to 40°C
storage/transport
-4°F to 122°F /
–20°C to 50°C
Rated service flow
(acc. to DIN 18879/NSF Std 42)
0.25 Gal/min
Pressure loss at nominal service flow
2.9 psi/
0.2 kg/cm
2
Empty filter cartridge volume
0.26 Gallon
Weight (dry/wet)
2.2 lb/3.1 lb
Dimensions
(Width/Depth/
Height)
Filter system
(filter head with filter
cartridge)
4.6"/4.3"/10.4"
Filter cartridge
4.3"/4.3"/10.2"
Installed dimensions
(vertical installation
with wall mounting
bracket)
5.4"/5.1"/10.4"
Operating position
Horizontal and
vertical
Water inlet connection
3/8" BSP
Water outlet connection
3/8" BSP
EN