background image

8.1 Important notes  

Please observe the 

safety notes

and the

important notes

(Chapter 1).

The installing technician

is responsible for

perfect functioning of the appliance at its
installation location. He must explain the operating
principle to the user with reference to the operating
instructions and must show how to switch of the
electricity and gas whenever required.

Caution:

Before connecting the appliance, please check
whether the

local connection conditions 

such as

the gas type, gas pressure and mains voltage and
the appliance settings are correct. Refer to the
adhesive label on the gas connection or the

rating

plate

for the necessary information. This gas hob

conforms to the categories that are specified on 
the rating plate. The rating plate can be found on
the appliance and additionally on the enclosed
addendum sheet. By replacing nozzles, it is
possible to set the appliance to any gas listed on
the rating plate. If the data should not agree, the
appliance must be set to the required gas type and
the available pressure.
As this gas hob is not intended for connection to an
exhaust gas system, pay attention to the applicable
installation conditions.

Note on ventilation:

To ensure good combustion, the room in which this
appliance is installed must have a minimum volume
of 10 m

3

and a door that opens out to outdoors or a

window that can be opened.

In Germany, the gas hob must be installed and
connected by a fitter who has been approved by
the gas supply company. At the same time, the
guidelines such as DVGW-TRGI 86 and TRF 1988
and the regulations of the gas supply companies
and of the responsible authorities must be
observed.

In Switzerland, the respectively applicable
regulations of SVGW and of the Association of
Cantonal Fire Insurance Companies as well as the
manufacturer's installation conditions must be
observed when installing the appliance.

In Austria, the ÖVGW-TR Gas (G1) and ÖVGW-TR
Flüssiggas (G2-Part 1) regulations and the local
construction and trade regulations must be
observed when installing the appliance.

The appliance may be installed in kitchen
combinations made of wood or similar combustible
materials without taking additional measures. The
rear wall must consist of non-combustible material.

A minimum distance of 

150 mm

from heat-sensitive

items of furnishing or contact surfaces (cupboard
side panel) must be observed.

The hob conforms to appliance class 3 and must be
installed in the worktop as shown in the installation
sketch.

The distance between the suspended cupboard
and the worktop must be at least

600 mm

. Attention

must be paid to the manufacturer's specified safety
clearance when a vapour extractor is installed. Wall
trims must be heat-resistant, and the minimum
distance between the hob and the wall trim is at
least 

35 mm

.

After unpacking, check the appliance for any
transportation damage and report this immediately
to the transportation company.

Technical modifications reserved.

13

8. Assembly instructions

VG 231-...

FDxxxx

AC 220-240V

50/60Hz      

Qn

5,0 kW
0,8  VA

Summary of Contents for VG 231 AU

Page 1: ...Operating and assembly instructions VG 231 Gas cooker...

Page 2: ...peration Page 7 4 Cleaning and care Page 8 5 Maintenance Page 9 5 1 General Page 9 5 2 Remedying slight malfunctions yourself Page 9 6 Technical data Table Page 10 7 Practical tips Page 11 12 7 1 Acce...

Page 3: ...d assembly instructions conscientiously before operating it for the first time The instructions contain important notes on use installation and maintenance of the appliance You will find notes on page...

Page 4: ...every maintenance operation To do this remove the mains plug or actuate the corresponding fuse Close the gas supply Repairs must be carried out by authorised specialists thus ensuring electrical safet...

Page 5: ...setting whenever you remove pots or pans briefly thus saving gas and reducing pollution Whenever the gas hob is fitted under a vapour extractor hood always cover the rings with pots or pans Otherwise...

Page 6: ...se for flame monitor 4 Pot support 5 Control knob for the cooking position 6 Burner cover 7 Burner ring 8 Burner head recess 9 Burner head You can order the following special accessories VV 200 000 co...

Page 7: ...al load amounts to 5 0 kW referred to Hs gross calorific value 4 5 kW referred to Hi calorific value The specified rated load is defined by installation of the fixed nozzles The gas hob is converted t...

Page 8: ...er to the left to the low position and then back to the high position after ignition It is often faster to ignite in the low position because the various gases have a differing ignition response Once...

Page 9: ...water and detergent This loosens even the most stubborn of soiling Do not use any abrasive agents and abrasive sponges As the result of heat development slight dis coloration can appear on the stainl...

Page 10: ...iance will invalidate any warranty claims Only ever use original spare parts 9 5 Maintenance Fault Remedy The burner does not ignite after several attempts Check whether the burner is correctly assemb...

Page 11: ...T BE CH DE BE FR LU NL DE BE CH DK ES AT DE DK ES FI FR FI FR GB GR GB GR IE IS IE IS IT LU IT LU NL PT NL NO PT SE SE Gas family Natural gas Natural gas Natural gas But Prop But Prop Gas type H E G 2...

Page 12: ...cooked as briefly as possible under strong heat and constant stirring In the large round pan everything can be stirred and turned faster and with greater ease than in a conventional frying pan Thanks...

Page 13: ...same time Briefly roast the garlic and ginger and add the meat cubes Reduce the heat Add the Tongku and oyster mushrooms spring onions oyster and fish sauce and the sugar and allow to cook for about...

Page 14: ...connected by a fitter who has been approved by the gas supply company At the same time the guidelines such as DVGW TRGI 86 and TRF 1988 and the regulations of the gas supply companies and of the resp...

Page 15: ...such a way that it cannot come into contact with moving parts of the kitchen element e g drawer Electrical connection Electrical connection AC 220 240 V is established by means of a connecting cable w...

Page 16: ...rner head If the appliance is connected rigidly to a gas main it must be disconnected from the gas network If it is connected via a gas safety hose the appliance only needs to be pushed out of its mou...

Page 17: ...gas leaks on the installed main nozzle According to the new gas type stick the included adhesive label over the data specified on the gas connection Adjust the air gap according to the table entitled...

Page 18: ...e flames burn stably and with low noise Yellow tips must not be visible in the flames The flame must not go off when you switch swiftly from the high to the low setting Firmly screw in the screw 2 aga...

Page 19: ...rking on the worktop Fig 17 Lower the appliance into the worktop Make sure that the engaging lugs on the appliance lie exactly on the clamping springs Press the appliance firmly into the worktop The e...