Service Bulletin

VK 111-610

 control boards 

must

 be reset and recalibrated whenever they’re

replaced or when steamers are moved to higher or lower elevations.  Use these
instructions to reset and recalibrate the control board.  Note the # 

165176

 calibration

(jumper) cable was changed -- alligator clips are no longer included.  To use the
jumper cable, provide alligator clips to connect the cable to the steamer.

NOTES:

  Replacement capacitors (part # 

169105)

 may look slightly differently and have a slightly different

rating than ones used on older steamers.  Older control boards may have three terminals (“

N

”, “

L

” & “

Out

”).

HINT:

  Parts needed for calibration:

Calibration jumper cable (# 

165176

)

Control board with capacitor (# 

265940

) or without capacitor (#

264735

)

Two (2) alligator clips (supplied by service technician)

VK 111-610

 steamer cover (check if customer can supply)

PROCEDURE FOR RESETTING CONTROL BOARD:

NOTE

:  The control board 

must

 be reset whenever it has been replaced and if basic calibration

has to be repeated (because of an error -- see fault codes on page 2).

1. Remove two (2) screws to open access panel at bottom rear of steamer.  Replace control board

if defective.

2. Connect cable 4-pin connector to terminal 

ST 5

 on right side of control board. Attach alligator

clips to ends of 

black

 and 

red

 calibration cable wires. Attach both wires (

black

 and 

red

) to

exposed wire on wire loop of cable.

3. Turn steamer 

on

 to 

reset control board

 -- when board has reset, steamer 

yellow

 indicator light

will flash five (5) times.  Turn steamer 

off

.

1st Edition/Rev. 1

# 165176

calibration jumper

cable without
alligator clips

Note no alligator clips are provided

Exposed

wire on

wire loop

4-pin

connector

Red

Black

HINT:

  Reset the control board and perform basic and

boiling point (elevation) calibrations whenever a 

VK 111-610

steamer is moved to a higher or lower elevation.

Thursday, December 27, 2001

VK 111-610 Steamer Calibration & Fault Codes

Control Board

Lamp

N

L

Out

Calibration

cable socket

ST 5

ST 4

ST 2

ST 3

To L2

To L1

(240 VAC)

To
element