ALARM
CAUSE
SOLUTION
Menu 1 - in the event of
synchronisation problems in the
machine software, a general
deactivation alarm appears.
- Switch the machine off, and
then back on again
- Make a factory pre-set in the
Technical menu (contact an
authorised Gaggia Milano
Aftersales Service for the
relative password)
- If possible, try to reload the
software on the machine
board
- Potential machine board
fault: check and replace
Menu 1 - when the heating
of the steam boiler is not
completed within the time limit
set in the software, alarm AL5
appears on every unit.
- Potential steam boiler
heating element fault: check
and replace
- Potential steam boiler safety
thermostat fault: check and
replace
- Potential wiring fault on
steam boiler heating
element: check and replace
- Potential solid state relay
fault: check and replace
- Potential machine board
fault: check and replace
Caution
If alarm AL1, AL2 or AL3 is activated, not only is the info given on the displays
concerned but all the dispensing buttons also start flashing.